Siemens SENTRON Series Residual Current Circuit Breaker, 63 A, 4-Pole, 300 mA, Type A, 10 kA 400 V ac
- RS-stocknr.:
- 211-9704
- Fabrikantnummer:
- 5SV3646-5KK14
- Fabrikant:
- Siemens
Subtotaal (1 eenheid)*
€ 1.767,50
(excl. BTW)
€ 2.138,68
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.767,50 |
*prijsindicatie
- RS-stocknr.:
- 211-9704
- Fabrikantnummer:
- 5SV3646-5KK14
- Fabrikant:
- Siemens
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63 A | |
| Number of Poles | 4 | |
| Range | SENTRON | |
| Series | SENTRON | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Standards/Approvals | UKCA, VDE, EAC, CE | |
| Terminal Type | Screw | |
| Depth | 70mm | |
| Width | 72 mm | |
| Height | 90mm | |
| Breaking Capacity | 10kA | |
| Tripping Mechanism | Electromagnetic | |
| Rated AC Voltage | 400 V ac | |
| Reset Actuator Type | Toggle Switch | |
| Break Time | Instantaneous | |
| Earth Leakage Protection Type | Type A | |
| Alles selecteren | ||
|---|---|---|
Merk Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63 A | ||
Number of Poles 4 | ||
Range SENTRON | ||
Series SENTRON | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Standards/Approvals UKCA, VDE, EAC, CE | ||
Terminal Type Screw | ||
Depth 70mm | ||
Width 72 mm | ||
Height 90mm | ||
Breaking Capacity 10kA | ||
Tripping Mechanism Electromagnetic | ||
Rated AC Voltage 400 V ac | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
Earth Leakage Protection Type Type A | ||
- Land van herkomst:
- DE
The Siemens Residual current operated circuit breaker has 4-pole and type Operating current is 63 A and trippening current 300 mA. Supply voltage is 400 These can generate residual currents at the output side, caused by a mixture of frequencies with frequency components in the kilohertz range. RCCBs, type F are best suited for this purpose, since they expand the range of functions offered by type A. They have an impulse withstand strength of > 3 kA and a current carrying capacity of up to 10 mA with smooth DC residual currents. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free