Siemens SENTRON Series Residual Current Circuit Breaker, 40 A, 4-Pole, 100 mA, Type AC, 10 kA 230 V ac
- RS-stocknr.:
- 231-8396
- Fabrikantnummer:
- 5SV4444-0
- Fabrikant:
- Siemens
Subtotaal (1 eenheid)*
€ 316,67
(excl. BTW)
€ 383,17
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- 1 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 316,67 |
*prijsindicatie
- RS-stocknr.:
- 231-8396
- Fabrikantnummer:
- 5SV4444-0
- Fabrikant:
- Siemens
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Range | SENTRON | |
| Series | SENTRON | |
| Trip Sensitivity | 100mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type AC | |
| Standards/Approvals | EAC, UKCA, VDE, CE | |
| Terminal Type | Screw | |
| Width | 72 mm | |
| Height | 90mm | |
| Depth | 70mm | |
| Breaking Capacity | 10kA | |
| Rated AC Voltage | 230 V ac | |
| Reset Actuator Type | Toggle Switch | |
| Earth Leakage Protection Type | AC | |
| Break Time | Instantaneous | |
| Alles selecteren | ||
|---|---|---|
Merk Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Range SENTRON | ||
Series SENTRON | ||
Trip Sensitivity 100mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type AC | ||
Standards/Approvals EAC, UKCA, VDE, CE | ||
Terminal Type Screw | ||
Width 72 mm | ||
Height 90mm | ||
Depth 70mm | ||
Breaking Capacity 10kA | ||
Rated AC Voltage 230 V ac | ||
Reset Actuator Type Toggle Switch | ||
Earth Leakage Protection Type AC | ||
Break Time Instantaneous | ||
- Land van herkomst:
- DE
The Siemens 5SV4 series is the residual current operated circuit breaker having 4 pole. The tripping characteristic class of this residual current operated circuit breaker is type AC and its rated current is 40A. The tripping fault current of circuit breaker is 100 mA.
IP degree of protection is IP20
Ambient temperature range is -25 °C to 45 °C
Shock resistance
Fastening method is DIN rail
Gerelateerde Links
- ABB RCCB 4 Pole Type F, 400V ac
- Siemens 5SV3 RCCB 4 Pole Type A, 400V ac
- Hager CEC RCCB 3P+N Pole Type AC, 230 → 400V ac
- Eaton RCCB 4 Pole Type A, 230/400V ac
- ABB F200 RCCB 4 Pole Type A, 230/400V ac
- ABB F200 RCCB 2 Pole Type A, 230/400V ac
- Siemens 5SV4446 RCCB 4 Pole Type AC, 400V ac
- Siemens 5SV4344 RCCB 4 Pole Type AC, 400V ac