SICK FXL1 Series Safety Controller, 2 Safety Outputs, 24V dc

Subtotaal (1 eenheid)*

€ 416,12

(excl. BTW)

€ 503,51

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 1 stuk(s) klaar voor verzending
  • Plus verzending 1 stuk(s) vanaf 18 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 416,12

*prijsindicatie

RS-stocknr.:
285-9512
Fabrikantnummer:
FXL1-SPBUSA00
Fabrikant:
SICK
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

SICK

Product Type

Safety Controller

Series

FXL1

Number of Safety Outputs

2

Safety Category

4

Supply Voltage

24V dc

Contact Current

100mA

Depth

45mm

Terminal Type

M12 Connector

Width

40mm

Length

194.4mm

IP Rating

IP65, IP69K, IP67

Land van herkomst:
MY

SICK FXL1 Series Safety Controller, 24V DC Supply Voltage, 2 Safety Outputs - FXL1-SPBUSA00


This safety controller provides monitored semiconductor safety outputs and diagnostics for machinery protection in industrial environments. Designed for use with plug-in M12 connections, it delivers safety-related switching and actuator monitoring while tolerating demanding ambient conditions. The unit supports safe series wiring and options for in-cabinet or field connection schemes, delivering dependable lock monitoring and application diagnostic signalling.

Features and Benefits:


• SIL3 safety integrity level enabling high-risk applications
• Category4 safety classification supporting interlocking monitoring
• Dual PNP OSSD outputs providing cross-circuit monitored protection
• ≤100mA output current limiting compatible with small loads
• IP65 IP67 IP69K enclosure rating allowing washdown environments

Applications


• Suitable for guarding and interlock monitoring on production lines
• Used with electromechanical safety locks requiring monitored outputs
• Ideal for safe series connections with Flexi Loop diagnostics
• Can be used for machine door locking monitoring and control

What power range is required for operation?


It requires a 24V DC supply within 19.2V DC to 28.8V DC.

How are the field connections implemented?


Connections use an 8-pin M12 plug connector with stainless-steel coupling.

What diagnostic signals are available?


It provides an auxiliary application diagnostic output Plus LEDs for status and diagnostics.

How fast does the device respond and release?


Response time is ≤150ms and release time is ≤350ms with increased series-connection delay per additional switch.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.