SICK FX3 Series Safety Controller Connector
- RS-stocknr.:
- 701-9187
- Fabrikantnummer:
- FX3-MPL000001
- Fabrikant:
- SICK
Bulkkorting beschikbaar
Subtotaal (1 eenheid)*
€ 45,55
(excl. BTW)
€ 55,12
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- 569 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 - 9 | € 45,55 |
| 10 - 14 | € 43,88 |
| 15 + | € 42,68 |
*prijsindicatie
- RS-stocknr.:
- 701-9187
- Fabrikantnummer:
- FX3-MPL000001
- Fabrikant:
- SICK
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | SICK | |
| Product Type | Safety Controller Connector | |
| Series | FX3 | |
| Standards/Approvals | RoHS | |
| Alles selecteren | ||
|---|---|---|
Merk SICK | ||
Product Type Safety Controller Connector | ||
Series FX3 | ||
Standards/Approvals RoHS | ||
- Land van herkomst:
- HU
Flexi Soft Safety Controller, Main unit - FX3 CPU000000
Flexi Soft is a programmable and modularly expandable safety controller capable of being integrated into various networks. The main module FX3-CPU is the CPU of the entire system within which all input signals are monitored and processed via the safety logic stored in the memory plug. These signals are then used to switch outputs on the system through the FLEX BUS+ interface which connects all units to one another. The main unit has an RS-232 interface with which the Flexi Soft Designer can upload and change system settings. The RS-232 port can be used for permanent diagnosis (i.e. PLC or HMI) as well.,Functions: EDM, muting, operating mode switching. Logical functions: AND, NOT, OR, XNOR, XOR. Application specific logical functions: operating mode switch, muting, emergency stop, presses, two hand control.,For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a system. The gateways provide I/O Status and Error/Status Messaging. Additionally, non-safety related information can be sent to the Flexi Soft from the network. Each gateway can send and receive at least 50 Bytes of information.
System save in memory plug for a fast installation
Modular expandable (from 12 to 144 in/outputs maximum)
2.5 W power consumption
Intuitive free to download software: Flexi Soft Designer
Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)
Note
The system memory plug (FX3-MPL) is sold separately
Gerelateerde Links
- SICK FX3 Series Safety Controller
- SICK FX3 Series Safety Controller, 24V dc
- SICK FX3 Series Safety Controller 13V dc, 30 V dc
- SICK 48 Safety Outputs
- SICK FX3 Series I/O Module
- SICK UE410 Series Safety Controller
- SICK MOC3SA Series Safety Controller, 24V
- SICK FX3 Series Wall Network Hub, 100Mbps Transmission