SICK FXL1 Safety Interlock Switch, Power, Vistal, Interlock
- RS-stocknr.:
- 139-826
- Fabrikantnummer:
- 1122586
- Fabrikant:
- SICK
Subtotaal (1 eenheid)*
€ 538,13
(excl. BTW)
€ 651,14
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- 1 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 538,13 |
*prijsindicatie
- RS-stocknr.:
- 139-826
- Fabrikantnummer:
- 1122586
- Fabrikant:
- SICK
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | SICK | |
| Product Type | Safety Interlock Switch | |
| Lock Style | Power | |
| Lock Type | Interlock | |
| Actuator Included | No | |
| Safety Contacts | 2 PNP | |
| Housing Material | Vistal | |
| Series | FXL1 | |
| IP Rating | IP65, IP69K, IP67 | |
| Switch Contact Current | 100mA | |
| Minimum Operating Temperature | -20°C | |
| Contact DC Voltage | 24V dc | |
| Maximum Operating Temperature | 55°C | |
| Hazardous Area Certification | No | |
| Width | 40mm | |
| Standards/Approvals | IEC 60529 | |
| Length | 180mm | |
| Depth | 48mm | |
| Alles selecteren | ||
|---|---|---|
Merk SICK | ||
Product Type Safety Interlock Switch | ||
Lock Style Power | ||
Lock Type Interlock | ||
Actuator Included No | ||
Safety Contacts 2 PNP | ||
Housing Material Vistal | ||
Series FXL1 | ||
IP Rating IP65, IP69K, IP67 | ||
Switch Contact Current 100mA | ||
Minimum Operating Temperature -20°C | ||
Contact DC Voltage 24V dc | ||
Maximum Operating Temperature 55°C | ||
Hazardous Area Certification No | ||
Width 40mm | ||
Standards/Approvals IEC 60529 | ||
Length 180mm | ||
Depth 48mm | ||
- Land van herkomst:
- MY
SICK FXL1 Series Safety Interlock Switch, 24V DC Supply Voltage, VISTAL Housing - 1122586
This safety interlock switch provides monitored locking for access points in industrial settings. It employs RFID sensing and a power-to-lock mechanism to prevent unauthorised opening while offering escape release capability. The unit is designed for integration into safety architectures with both cabinet-based and Flexi Loop diagnostics and connects via an 8‑pin M12 plug. It is suitable for environments requiring rugged protection and electrical safety outputs.
Features and Benefits:
• SIL3 and PL e safety level supports high-risk applications
• 2 PNP semiconductor safety outputs limit output current to 100mA
• Power-to-lock concept permits controlled locking and escape release
• IP65, IP67, IP69K enclosure resists dust and high‑pressure washdowns
• Operating range -20°C to +55°C covers varied ambient conditions
• 2 PNP semiconductor safety outputs limit output current to 100mA
• Power-to-lock concept permits controlled locking and escape release
• IP65, IP67, IP69K enclosure resists dust and high‑pressure washdowns
• Operating range -20°C to +55°C covers varied ambient conditions
Applications
• Suitable for guarded doors requiring locking and monitored release
• Ideal for machine safety chains with series diagnostics
• Used with safety relays and Flexi Compact controllers
• Can be used for hygienic wash‑down environments in production
• Suitable for installations needing coded RFID actuator identification
• Ideal for machine safety chains with series diagnostics
• Used with safety relays and Flexi Compact controllers
• Can be used for hygienic wash‑down environments in production
• Suitable for installations needing coded RFID actuator identification
What type of outputs does it provide for safety circuits?
It provides two self‑monitoring semiconductor OSSD outputs implemented as PNP devices with cross‑circuit monitoring.
How is the device powered and what are its supply limits?
It runs from a 24V DC supply with an allowable range of 19.2V DC to 28.8V DC.
Which connector and cable Interface is required for integration?
The unit uses an 8‑pin M12 plug connector with a stainless‑steel coupling nut and requires compatible M12 connection cables.
What are the response and release characteristics relevant to safety timing?
Response time is ≤150 MS, release time is ≤350 MS and risk time is 150 MS, with series connection adding 70 MS per additional device.
What mechanical endurance and materials support durability?
Mechanical life is rated at 1x10^6 switching cycles and the housing is manufactured from VISTAL® with stainless‑steel brackets and plug components.
Gerelateerde Links
- SICK FLX1 Safety Interlock Switch Vistal, Interlock
- SICK i200 Safety Interlock Switch Vistal
- SICK MB1 Safety Interlock Switch, Vistal
- SICK TR4 Safety Interlock Switch Vistal
- SICK STR1 Safety Interlock Switch Vistal
- SICK RE15 Safety Interlock Switch Vistal, Magnet
- SICK RE13 Safety Interlock Switch Vistal, Magnet
- SICK STR1 Safety Interlock Switch Actuator Included, Vistal