SICK TR4 Safety Interlock Switch, RFID Actuator Included, Vistal
- RS-stocknr.:
- 285-9057
- Fabrikantnummer:
- TR4-SAU01CB
- Fabrikant:
- SICK
Subtotaal (1 eenheid)*
€ 210,08
(excl. BTW)
€ 254,20
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- 2 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 210,08 |
*prijsindicatie
- RS-stocknr.:
- 285-9057
- Fabrikantnummer:
- TR4-SAU01CB
- Fabrikant:
- SICK
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | SICK | |
| Product Type | Safety Interlock Switch | |
| Lock Style | RFID | |
| Actuator Included | Yes | |
| Safety Contacts | 2 | |
| Housing Material | Vistal | |
| Series | TR4 | |
| IP Rating | IP67, IP69K | |
| Switch Contact Current | 200mA | |
| Contact AC Voltage | 230V ac | |
| Contact DC Voltage | 24V dc | |
| Minimum Operating Temperature | -25°C | |
| Hazardous Area Certification | No | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | IEC 60529 | |
| Width | 67.1mm | |
| Length | 67.1mm | |
| Number of Head Directions | 5 | |
| Alles selecteren | ||
|---|---|---|
Merk SICK | ||
Product Type Safety Interlock Switch | ||
Lock Style RFID | ||
Actuator Included Yes | ||
Safety Contacts 2 | ||
Housing Material Vistal | ||
Series TR4 | ||
IP Rating IP67, IP69K | ||
Switch Contact Current 200mA | ||
Contact AC Voltage 230V ac | ||
Contact DC Voltage 24V dc | ||
Minimum Operating Temperature -25°C | ||
Hazardous Area Certification No | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals IEC 60529 | ||
Width 67.1mm | ||
Length 67.1mm | ||
Number of Head Directions 5 | ||
- Land van herkomst:
- DO
SICK TR4 Series Safety Interlock Switch, IP67, Vistal Housing - TR4-SAU01CB
This safety interlock switch is a non-contact RFID device designed to monitor access to guarded machinery. It provides dual safe outputs with self-monitoring semiconductor circuitry and is intended for integration into safety systems requiring high integrity and diagnostic options. The unit is suitable for use where contamination or washdown are present and operates across a wide ambient temperature range.
Features and Benefits:
• SIL3 safety integrity enhances functional safety performance
• Category 4 design ensures highest risk-reduction level
• Two OSSD outputs provide monitored switching capability
• Encapsulated electronics deliver IP67 and IP69K ingress protection
• Self-monitoring outputs limit output current to 200mA
• Category 4 design ensures highest risk-reduction level
• Two OSSD outputs provide monitored switching capability
• Encapsulated electronics deliver IP67 and IP69K ingress protection
• Self-monitoring outputs limit output current to 200mA
Applications
• Suitable for washdown production lines in food environments
• Ideal for linking multiple guards with Flexi Loop diagnostics
• Used with safe evaluation units in machine safety circuits
• Can be used for non-hazardous area interlocks in factories
• Suitable for conveyor and packaging guard monitoring
• Ideal for linking multiple guards with Flexi Loop diagnostics
• Used with safe evaluation units in machine safety circuits
• Can be used for non-hazardous area interlocks in factories
• Suitable for conveyor and packaging guard monitoring
What supply voltage does it require?
It is powered from 24V DC within a 20.4V DC to 26.4V DC range.
How are connections MADE to a control system?
It uses an 8-pin M12 cable plug with a 0.2m pigtail and supports long cables up to 200m.
What mechanical stresses can it withstand?
The device resists vibration from 10Hz to 55Hz at 3.5mm and shock up to 30g for 11 ms.
How quickly does it respond to a safety event?
Nominal response time is 45 MS with a release time of 360 MS and switch-on time of 2 s.
What diagnostic or series-connection options exist?
It supports series connection with Flexi Loop for diagnostics and T-connector use without diagnostics.
Gerelateerde Links
- SICK TR4 Safety Interlock Switch Vistal
- SICK TR4 Safety Interlock Switch Valox
- SICK STR1 Safety Interlock Switch Vistal
- SICK TR4 Safety Switch Valox
- SICK STR1 Safety Switch Vistal
- SICK STR1 Safety Switch Vistal, Electronic
- SICK STR1 Safety Interlock Switch Actuator Included, Vistal
- SICK TR4 Safety Interlock Switch Fibreglass Polyester, Electronic