Pilz PNOZ s1, 24 V dc Safety Relay, 2 Safety Contacts
- RS-stocknr.:
- 155-939
- Artikelnummer Distrelec:
- 304-10-471
- Fabrikantnummer:
- 750101
- Fabrikant:
- Pilz
Subtotaal (1 eenheid)*
€ 168,29
(excl. BTW)
€ 203,63
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- Plus verzending 21 stuk(s) vanaf 09 maart 2026
- Plus verzending 112 stuk(s) vanaf 09 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 168,29 |
*prijsindicatie
- RS-stocknr.:
- 155-939
- Artikelnummer Distrelec:
- 304-10-471
- Fabrikantnummer:
- 750101
- Fabrikant:
- Pilz
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Pilz | |
| Product Type | Safety Relay | |
| Safety Contacts | 2 | |
| Contact Configuration | 2 NO | |
| Reset Method | Automatic & Manual | |
| Mount Type | DIN Rail | |
| Series | PNOZ s1 | |
| Power Consumption | 2W | |
| Terminal Type | Screw | |
| IP Rating | IP20, IP40, IP54 | |
| Switching DC Voltage | 24 V dc | |
| Switching AC Voltage | 240 V ac | |
| Standards/Approvals | EN 954-1, VDE 0113-1, EN 60068-2-6, EN 61000-6-2, EN 60947-5-1, EN 61000-6-4, EN 60947-4-1, EN 60204-1, EN 60947-1, EN ISO 13849-1, EN 60068-2-78 | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 55°C | |
| Height | 120mm | |
| Width | 12.5 mm | |
| Length | 100mm | |
| Safety Category | CAT 2, EN ISO 13849-1, EN 954-1 | |
| Hazardous Area Certification | No | |
| Coil Voltage | 24 V dc | |
| Alles selecteren | ||
|---|---|---|
Merk Pilz | ||
Product Type Safety Relay | ||
Safety Contacts 2 | ||
Contact Configuration 2 NO | ||
Reset Method Automatic & Manual | ||
Mount Type DIN Rail | ||
Series PNOZ s1 | ||
Power Consumption 2W | ||
Terminal Type Screw | ||
IP Rating IP20, IP40, IP54 | ||
Switching DC Voltage 24 V dc | ||
Switching AC Voltage 240 V ac | ||
Standards/Approvals EN 954-1, VDE 0113-1, EN 60068-2-6, EN 61000-6-2, EN 60947-5-1, EN 61000-6-4, EN 60947-4-1, EN 60204-1, EN 60947-1, EN ISO 13849-1, EN 60068-2-78 | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 55°C | ||
Height 120mm | ||
Width 12.5 mm | ||
Length 100mm | ||
Safety Category CAT 2, EN ISO 13849-1, EN 954-1 | ||
Hazardous Area Certification No | ||
Coil Voltage 24 V dc | ||
PNOZ S1 series by PILZ
The PNOZ S1 series of Safety relay by PILZ. Known for their reliability and durability, PILZ safety relays offer you second to none safety protection features to ensure you and your workplace stay safe. Specifically, the S1 series is suitable for many different applications which you can find listed below.
Features and benefits:
• LED display that offers you the following measures:
- Supply voltage
- Input status, channel 1
- Input status, channel 2
- Switch status, safety contacts
- Reset Circuit
- Error indication
Safety features
• Self-monitoring built in
• Safety functions remain effective in the case of components failure
• Correct opening and closing is tested automatically at the end of each on / off cycle
• The transform uses an electronic fuse which prevents short circuiting.
Applications
• E STOP pushbutton
• Safety gate limit switches
• Reset buttons
Technical safety parameters
• EN 60947-5-1
• EN 60204-1
• VDE 0113-1
How do Safety Relays work and what are they used for?
Safety Relays work by helping reduce unnecessary risk and hazard within your circuit. A typical circuit configuration may look like a production line where highly automated machinery works quickly, i.e. a production or packing line in a warehouse or factory. This line forms part of your 'circuit' and along that circuit you will have safety devices in place like emergency push buttons, safety curtains or pressure sensitive mats. To ensure complete safety in these environments, a safety relay can be added to your circuit to allow you full control and monitoring of your working environment. A safety relay will run regular checks down your circuit by sending pulses back and forth to confirm whether any (for example) wiring was implemented incorrectly or any welding has occurred along the circuit. Once the relay has detected this, it would then shut down the area by cutting off the power, until the fault can be determined and fixed. Most recent safety relays feature intuitive LED displays that will alert users to any faults, this is of course useful to prevent harm to users and also proactively engage in maintenance before any machinery is damaged beyond repair, so certain cost savings can be associated when using a safety relay.
Some safety relays have specific functions and only work with certain devices like E-STOPs, some work better with other devices like safety curtains. More than one safety relay can be used to give you total monitoring of your circuit, ensuring you and your employees safety.
What are the differences between a traditional 'relay' and a 'safety relay'?
A traditional relay will open and close your circuit and the switch devices down that line, however it will not monitor it in the same way a safety relay will and cannot automatically shut down specified areas to prevent harm to the machinery or workers. Safety relays are not prone to the same potential risks that traditional relays are and can be relied upon to monitor short circuit faults, ground faults or wire breakage. Offering a greater protection over their counterpart relays, they are specifically designed with your safety in mind.
How do you operate a Safety Relay?
You must first align and wire the safety relay into your line and follow the setup instructions provided (will vary per manufacturer). Follow the onscreen instructions of the LED parallel to your instructions to perform integration into your circuit line. Depending on what parameters you set will determine the function of the safety relay (i.e. you tell it to cut off certain areas after certain criteria have been met, or you opt for a circuit wide halt of the line).
Gerelateerde Links
- Pilz PNOZsigma PNOZ s1 C Safety Relay 24V dc, Dual-Channel 2 Safety Contacts
- Pilz PNOZsigma PNOZ s7 C Safety Relay 24V dc
- Pilz PNOZsigma PNOZ s2 1 Auxiliary Contacts Safety Relay 24V dc, Single Channel 3 Safety Contacts
- Pilz PNOZsigma PNOZ s4 C Safety Relay 24V dc, Dual-Channel
- Pilz PNOZsigma PNOZ s3 Safety Relay 24V dc, Dual-Channel 2 Safety Contacts
- Pilz PNOZsigma PNOZ s5 Safety Relay 24V dc, Dual-Channel 2 Safety Contacts
- Pilz PNOZsigma PNOZ s5 C Safety Relay 24V dc, Dual-Channel 2 Safety Contacts
- Pilz PNOZsigma PNOZ s3 C Safety Relay 24V dc, Dual-Channel 2 Safety Contacts