Lapp CY Control Cable, 5 Cores, 0.5 mm² CSA 20 AWG, Screened, 50 m, Transparent Polyvinyl Chloride Sheath

Subtotaal (1 rol van 50 meter)*

€ 187,91

(excl. BTW)

€ 227,37

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Bestellingen onder € 75,00 (excl. BTW) € 5,95.
Op voorraad
  • 3 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 187,91€ 3,758

*prijsindicatie

RS-stocknr.:
727-1467
Fabrikantnummer:
00352013
Fabrikant:
Lapp

LAPP ÖLFLEX CLASSIC 100 CY Series Control Cable, 0.5mm² Cross Sectional Area, 50m Length - 00352013


This control cable is designed for versatility in various industrial applications. With a round shape and an outer diameter of 8.4mm, it features a transparent PVC outer sheath and a reliable bare copper conductor for optimal performance. Rated for voltages up to 300/500 V, it operates effectively in both fixed and occasional flexing situations, making it ideal for dynamic environments.

Features & Benefits


• Transparent PVC sheath allows for visual inspection of cable integrity

• Screened design reduces electromagnetic interference

• Rated for high voltage performance up to 4kV

• Flame-retardant materials enhance safety standards

• Good chemical resistance ensures durability in demanding environments

Applications


• Suitable for plant engineering and construction

• Ideal for use in industrial machinery environments

• Effective in air conditioning installations for control

• Utilised in conveying and transport systems for reliability

• Optimal for servo drive in automation

What type of conductor and materials are used in this cable?


The cable employs fine strands of bare copper as conductors, combined with PVC materials for insulation and sheath, ensuring both flexibility and protection.

How does the voltage rating impact the use of this cable?


A voltage rating of 300/500 V signifies suitability for a wide range of applications, allowing for consistent performance in both fixed installations and flexible settings.

What is the minimum bend radius for installation?


For fixed installations, the minimum bend radius is six times the cable diameter, while for occasional flexing, it is advised to maintain a radius of twenty times the diameter for optimal lifespan.

Can this cable be used in environments where electromagnetic interference is a concern?


Yes, the screened design effectively reduces electromagnetic interference, making it well-suited for EMI-critical environments.

What temperatures can this cable withstand during operation?


This cable can operate within a temperature range from -40°C to +80°C, ensuring performance in various environmental conditions.