Sensata / Crydom Solid State Relay, 50 A rms Load, Panel Mount, 280 V rms Load, 32 V Control
- RS-stocknr.:
- 480-627
- Fabrikantnummer:
- MCBC2450AF
- Fabrikant:
- Sensata / Crydom
Afbeelding representeert productcategorie
Niet beschikbaar
RS heeft dit product niet meer op voorraad.
- RS-stocknr.:
- 480-627
- Fabrikantnummer:
- MCBC2450AF
- Fabrikant:
- Sensata / Crydom
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Sensata / Crydom | |
| Maximum Load Current | 50 A rms | |
| Mounting Type | Panel Mount | |
| Maximum Load Voltage | 280 V rms | |
| Maximum Control Voltage | 32 V | |
| Switching Type | DC | |
| Control Voltage Range | 8 → 32 V dc | |
| Minimum Load Current | 150 mA | |
| Load Voltage Range | 180 → 280V ac | |
| Dimensions | 58.4 x 45.7 x 19.8mm | |
| Depth | 45.7mm | |
| Height | 19.8mm | |
| Length | 58.4mm | |
| Operating Temperature Range | -20 → +80°C | |
| Maximum Operating Temperature | +80°C | |
| Minimum Operating Temperature | -20°C | |
| Alles selecteren | ||
|---|---|---|
Merk Sensata / Crydom | ||
Maximum Load Current 50 A rms | ||
Mounting Type Panel Mount | ||
Maximum Load Voltage 280 V rms | ||
Maximum Control Voltage 32 V | ||
Switching Type DC | ||
Control Voltage Range 8 → 32 V dc | ||
Minimum Load Current 150 mA | ||
Load Voltage Range 180 → 280V ac | ||
Dimensions 58.4 x 45.7 x 19.8mm | ||
Depth 45.7mm | ||
Height 19.8mm | ||
Length 58.4mm | ||
Operating Temperature Range -20 → +80°C | ||
Maximum Operating Temperature +80°C | ||
Minimum Operating Temperature -20°C | ||
- Land van herkomst:
- MX
MCBC- Burst Fire Controller
This device regulates the speed of an on/off pulse. Provides a smooth proportional control that minimizes electrical noise by utilizing zero-cross detection and switching, firing only complete AC cycles. Specialized Phase Detection Circuitry allows the MCBC to be connected to only one side of the load, minimizing installation wiring. Particularly suitable for use in heating applications where the electrical noise generated by typical phase angle controllers cannot be tolerated.
Burst Fire Controller / SSR in one package
Low Voltage, current or potentiometer control
Output status indicator (load open, no voltage)
0-100% Control Range
10 AC cycle time base period
Dielectric strength 50/60Hz, input/output/base: 4000Vrms
Separate output enable / disable control
SCR based output load switching
Internal snubber network included
Low Voltage, current or potentiometer control
Output status indicator (load open, no voltage)
0-100% Control Range
10 AC cycle time base period
Dielectric strength 50/60Hz, input/output/base: 4000Vrms
Separate output enable / disable control
SCR based output load switching
Internal snubber network included
Note
Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet
Proportional and Power
Note
Temperature can affect current rating; please consult the data sheet for potential derating.
Gerelateerde Links
- Sensata Crydom Solid State Relay Surface Mount 280 V rms Control
- Sensata Crydom Solid State Relay Surface Mount 280 V rms Control
- Sensata / Crydom Solid State Relay Surface Mount 280 V rms Control
- Sensata Crydom Solid State Relay Panel Mount 280 V rms Control
- Sensata Crydom Solid State Relay Panel Mount 280 V rms Control
- Sensata Crydom Solid State Relay PCB Mount, 280 V rms Load
- Sensata Crydom 1 Series Solid State Relay Panel Mount 280 V rms Control
- Sensata Crydom CW Series Solid State Relay Panel Mount 280 V rms Control