Sensata / Crydom Miniature Circuit Breaker Series Solid State Relay, 50 A Load, Panel Mount, 280 Vrms Load, 32V Control

Afbeelding representeert productcategorie

Bulkkorting beschikbaar

Subtotaal (1 eenheid)*

€ 140,37

(excl. BTW)

€ 169,85

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 4 stuk(s) vanaf 23 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 - 4€ 140,37
5 - 9€ 133,37
10 - 24€ 126,35
25 - 49€ 119,33
50 +€ 112,31

*prijsindicatie

RS-stocknr.:
480-655
Fabrikantnummer:
MCBC2450CF
Fabrikant:
Sensata / Crydom
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Sensata / Crydom

Maximum Load Current

50A

Product Type

Solid State Relay

Mount Type

Panel

Maximum Load Voltage

280Vrms

Minimum Load Voltage

180V

Maximum Control Voltage

32V

Minimum Control Voltage

0V ac

Series

Miniature Circuit Breaker

Terminal Type

Screw

IP Rating

IP20

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

80°C

Length

58.4mm

Width

22.6 mm

Standards/Approvals

UR, RoHS, CSA

Height

19.8mm

Capacitance

8pF

Off State Leakage Current

1mA

Output Type

SSR

MCBC- Burst Fire Controller


This device regulates the speed of an on/off pulse. Provides a smooth proportional control that minimizes electrical noise by utilizing zero-cross detection and switching, firing only complete AC cycles. Specialized Phase Detection Circuitry allows the MCBC to be connected to only one side of the load, minimizing installation wiring. Particularly suitable for use in heating applications where the electrical noise generated by typical phase angle controllers cannot be tolerated.

Burst Fire Controller / SSR in one package

Low Voltage, current or potentiometer control

Output status indicator (load open, no voltage)

0-100% Control Range

10 AC cycle time base period

Dielectric strength 50/60Hz, input/output/base: 4000Vrms

Separate output enable / disable control

SCR based output load switching

Internal snubber network included

Proportional and Power


Note

Temperature can affect current rating; please consult the data sheet for potential derating.

Gerelateerde Links