Huber+Suhner, 3402 Surge Suppressor Unit 230V Maximum Voltage Rating 30 kA Maximum Surge Current EMP Protector
- RS-stocknr.:
- 111-642
- Artikelnummer Distrelec:
- 304-16-644
- Fabrikantnummer:
- 3402.17.A
- Fabrikant:
- Huber+Suhner
Subtotaal (1 eenheid)*
€ 330,84
(excl. BTW)
€ 400,32
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 330,84 |
*prijsindicatie
- RS-stocknr.:
- 111-642
- Artikelnummer Distrelec:
- 304-16-644
- Fabrikantnummer:
- 3402.17.A
- Fabrikant:
- Huber+Suhner
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Huber+Suhner | |
| Product Type | Surge Suppressor Unit | |
| Suppressor Type | EMP Protector | |
| Maximum Voltage | 230V | |
| Mount Type | Panel Mount | |
| Maximum Surge Current | 30kA | |
| Series | 3402 | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Depth | 69mm | |
| Height | 25.9mm | |
| Length | 69mm | |
| Standards/Approvals | IEC 61643-21 | |
| Hazardous Area Certification | No | |
| Alles selecteren | ||
|---|---|---|
Merk Huber+Suhner | ||
Product Type Surge Suppressor Unit | ||
Suppressor Type EMP Protector | ||
Maximum Voltage 230V | ||
Mount Type Panel Mount | ||
Maximum Surge Current 30kA | ||
Series 3402 | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Depth 69mm | ||
Height 25.9mm | ||
Length 69mm | ||
Standards/Approvals IEC 61643-21 | ||
Hazardous Area Certification No | ||
Huber+Suhner Surge Suppressor Unit, 20kA Maximum Surge Current, 230V Maximum Voltage - 3402.17.A
This surge suppressor unit provides transient protection for electrical systems in industrial settings, designed for panel mounting and hostile temperature conditions. It intercepts high-energy electromagnetic pulses and lightning-induced transients to protect connected equipment, complying with recognised performance standards for surge protection devices.
Features and Benefits:
• 20 kA maximum surge current capability provides high-energy absorption
• Rated for 230V operation to match common supply systems
• EMC surge protection type suited to electromagnetic Pulse events
• Panel-mount configuration enables secure front- or rear-panel installation
• Operational range from -40 °C to 85 °C supports harsh environments
• Certified to IEC 61643-21 ensuring standardised performance assessment
• Rated for 230V operation to match common supply systems
• EMC surge protection type suited to electromagnetic Pulse events
• Panel-mount configuration enables secure front- or rear-panel installation
• Operational range from -40 °C to 85 °C supports harsh environments
• Certified to IEC 61643-21 ensuring standardised performance assessment
Applications
• Suitable for protection of automation controllers in switchgear panels
• Ideal for safeguarding industrial electronics against lightning strikes
• Used with power distribution modules in manufacturing facilities
• Can be used for transient protection of communication interfaces in control cabinets
• Ideal for safeguarding industrial electronics against lightning strikes
• Used with power distribution modules in manufacturing facilities
• Can be used for transient protection of communication interfaces in control cabinets
How is the unit typically installed in a control panel?
It is designed for panel-mount fixing, allowing direct attachment to panel cut-outs or mounting brackets for Compact integration within electrical enclosures.
What environmental conditions can it withstand during continuous operation?
The device is rated to operate across a wide temperature span from -40 °C up to 85 °C, accommodating cold storage areas and heat-generating equipment rooms.
Which standard verifies its surge protection performance?
Its compliance is assessed against IEC 61643-21, which covers requirements and testing methods for surge protective devices for low-voltage distribution.
How does it address EMP-type disturbances specifically?
The suppressor is configured as an EMP protector, providing targeted mitigation of short-duration, high-energy electromagnetic transients to reduce equipment upset and damage.
Note
Gas capsule included except for stock number 111-642 the Gas capsule must be ordered separately, stock no. 494-919
Gerelateerde Links
- Huber+Suhner, 3406 Surge Suppressor Unit 200V Maximum Voltage Rating 10 kA Maximum Surge Current EMP Protector
- Weidmüller, 1348 Surge Suppressor Unit 48V Maximum Voltage Rating 10 kA Maximum Surge Current Cat-6 Surge Protector
- Sollatek, PureAC13 Surge Suppressor Unit 250 V Maximum Voltage Rating 13A Maximum Surge Current Mains Protector
- WAGO, 792 Surge Suppressor Unit 60V Maximum Voltage Rating 0.1 A Maximum Surge Current Overvoltage Protector
- WAGO, 792 Surge Suppressor Unit 60V Maximum Voltage Rating 1.7 A Maximum Surge Current Overvoltage Protector
- WJ Furse, ESP Surge Suppressor Unit 16.7V Maximum Voltage Rating 20 kA Maximum Surge Current RS485 Surge Protector
- TE Connectivity, FP Surge Suppressor Unit 250V ac Maximum Voltage Rating 13.5 kA Maximum Surge Current Mains Protector
- RS PRO, BS1363 Surge Suppressor Unit 230V ac Maximum Voltage Rating 13.5 kA Maximum Surge Current Mains Protector