Entrelec, M 4/9 PV Surge Suppressor Unit 130V dc Maximum Voltage Rating 2.5 kA Maximum Surge Current Terminal Block with
- RS-stocknr.:
- 413-2397
- Fabrikantnummer:
- 1SNA007013R1300
- Fabrikant:
- Entrelec
Afbeelding representeert productcategorie
Subtotaal (1 eenheid)*
€ 11,79
(excl. BTW)
€ 14,27
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Tijdelijk niet op voorraad
- Verzending vanaf 30 december 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 11,79 |
*prijsindicatie
- RS-stocknr.:
- 413-2397
- Fabrikantnummer:
- 1SNA007013R1300
- Fabrikant:
- Entrelec
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Entrelec | |
| Product Type | Surge Suppressor Unit | |
| Suppressor Type | Terminal Block with Transient Voltage Suppressor | |
| Maximum Voltage | 130V dc | |
| Mount Type | DIN Rail | |
| Maximum Surge Current | 2.5kA | |
| Series | M 4/9 PV | |
| Minimum Operating Temperature | -55°C | |
| Maximum Operating Temperature | 130°C | |
| Standards/Approvals | ANSI/ESD S20.20:2014 | |
| Height | 100mm | |
| Length | 65.5mm | |
| Depth | 64.5mm | |
| Hazardous Area Certification | No | |
| Alles selecteren | ||
|---|---|---|
Merk Entrelec | ||
Product Type Surge Suppressor Unit | ||
Suppressor Type Terminal Block with Transient Voltage Suppressor | ||
Maximum Voltage 130V dc | ||
Mount Type DIN Rail | ||
Maximum Surge Current 2.5kA | ||
Series M 4/9 PV | ||
Minimum Operating Temperature -55°C | ||
Maximum Operating Temperature 130°C | ||
Standards/Approvals ANSI/ESD S20.20:2014 | ||
Height 100mm | ||
Length 65.5mm | ||
Depth 64.5mm | ||
Hazardous Area Certification No | ||
Vrijgesteld
Surge Protected Terminal Block
Grey nylon polyamide 6.6 moulding
Captive terminal screws with hardened heads
Compact 9mm spacing size
Deep Top Hat or G type rail mounting
Location category Zone 2
Dimensions 65.5 x 67mm
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Gerelateerde Links
- Murrelektronik Limited, Limited Surge Suppressor Surge Suppressor Unit 400V ac Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, Limited Surge Suppressor Surge Suppressor Unit 575V ac Maximum Voltage Rating Surge Suppressor
- Siemens, 3TX7402 Surge Suppressor Unit 150V Maximum Voltage Rating Surge Suppressor
- Siemens, 3TX7402 Surge Suppressor Unit 250V Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, 236082 Surge Suppressor Unit 575V Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, 23115 Surge Suppressor Unit 400V Maximum Voltage Rating Surge Suppressor
- Murrelektronik Limited, 23011 Surge Suppressor Unit 400V Maximum Voltage Rating Surge Suppressor
- WAGO, 792 Surge Suppressor Unit 24V dc Maximum Voltage Rating 300 A Maximum Surge Current Surge Suppressor