Fluke calibration 9100S-C-256 Temperature Calibrator

Subtotaal (1 eenheid)*

€ 2.731,00

(excl. BTW)

€ 3.304,51

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending 1 stuk(s) vanaf 28 januari 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 2.731,00

*prijsindicatie

RS-stocknr.:
284-2720
Fabrikantnummer:
9100S-C-256
Fabrikant:
Fluke calibration
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Fluke calibration

Resolution

0.1 °C

Product Type

Temperature Calibrator

Calibrator Type

Drywell Calibrator

Accuracy

±0.25°C

Thermocouple Type

RTD

Temperature Scale

°C, Fahrenheit, F

Minimum Thermocouple Temperature

-10°C

Length

150mm

Height

57mm

Weight

1kg

Standards/Approvals

No

Width

125mm

Land van herkomst:
US

Fluke Temperature Calibrator, ±0.25°C Accuracy, 0.1°C Resolution - 9100S-C-256


This temperature calibrator is a handheld dry-well device designed for portable verification of industrial temperature sensors. It provides a compact, field-ready solution for checking RTDs, thermocouples and small bimetal thermometers across a wide temperature span while offering selectable display in °C or Fahrenheit.

Features and Benefits:


• Accuracy ±0.25°C at 50°C for precise measurement assurance
• Resolution 0.1°C for fine-grain comparison of sensors
• Stabilisation time 5 minutes to reduce downtime during checks
• RS-232 interface for straightforward data exchange with computers
• Weight 1 kg enabling easy transport between sites
• Well depth 102mm to accommodate short-length probes

Applications


• Suitable for on-site verification of RTD sensors in process plants
• Ideal for thermocouple checking in maintenance routines
• Used with small bimetal thermometers for quick field audits
• Can be used for laboratory checks of RTD components
• Applicable to calibration of industrial temperature sensors in situ

What power options are available for field operation?


It accepts mains power at standard voltages and frequencies

power consumption varies with supply configuration and heating demand.

How quickly does it heat from ambient to elevated temperatures?


Typical heating time from 35°C to 375°C is approximately 9.5 minutes, enabling rapid test cycles.

Which sensor insertion sizes are supported?


The well accepts probes accommodated by supplied and optional removable inserts for differing probe diameters.

What uniformity can be expected across the well?


Well-to-well uniformity is maintained within tight limits when sensors of similar size are placed at equal depths.

Gerelateerde Links