Jumo Jumo TYA-200 DIN Rail, DIN Rail Power Controller Teach-In Self-Learning

Subtotaal (1 eenheid)*

€ 873,52

(excl. BTW)

€ 1.056,96

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 27 april 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 873,52

*prijsindicatie

RS-stocknr.:
793-4048
Artikelnummer Distrelec:
301-42-418
Fabrikantnummer:
709061/8-01-050-001-400-00/252
Fabrikant:
Jumo
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Jumo

Product Type

Power Controller

Maximum Current

250A

Minimum Operating Temperature

0°C

Maximum Operating Temperature

45°C

Control Type

Teach-In Self-Learning

Energy measurement

Yes

Firing Mode

Burst Fire, Phase Angle Operation

Diagnostics

Integrated Diagnostic, Rotary Field Detection

Digital Comms

RS485, PROFIBUS-DP, RS422 (Modbus RTU)

Maximum Voltage

500V

Display Type

LCD

IP Rating

IP20

Standards/Approvals

No

Series

Jumo TYA-200

Mount Type

DIN Rail, DIN Rail

Land van herkomst:
DE

TYA-201 1-Phase Power Controller


The micro-processor controlled single-phase power controller Jumo TYA 201 displays all parameters in a backlighted LCD display and is operated using the 4 keys on the front.

SCR power controllers are employed where larger resistive and inductive loads have to be switched, e.g. in industrial kiln construction and in plastics processing. The SCR power controller comprises two SCRs connected in anti-parallel, the insulated cooling body and the control electronics.

The operating modes are phase-angle, burst-firing mode, half-wave control, SSR logical operation , fast logical operation, alpha start and soft start.

Available subordinate controls are U, U2, I, I2 and P control.

Use of a subordinate control ensures that fluctuations in the supply voltage do not affect the control loop during the control process.

Single-phase SCR power controller

Simple configuration of the device through plain text display

Setup program for configuration via USB interface

Transmission of the setup data is possible even without voltage supply to the device (USB port supplies power)

Network load optimization through dual energy management

Generalized phase mode, burst-firing mode, and half-wave control

Soft start function

Current limiting

Resistance monitoring and limitation for MoSi2 heating elements

Teach-in function for the detection of partial load failure

Integrated diagnostic systems (e.g. rotating field detection)

Gerelateerde Links