Amphenol Advanced Sensors Polyvinylidene Fluoride NTC NTC Thermistor, 0 °C Min, 50 °C Max, 2.03 mm Probe
- RS-stocknr.:
- 257-9512
- Fabrikantnummer:
- MA100GG232C
- Fabrikant:
- Amphenol Advanced Sensors
Subtotaal (1 zak van 1000 eenheden)*
€ 3.672,00
(excl. BTW)
€ 4.443,00
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Tijdelijk niet op voorraad
- Verzending vanaf 19 augustus 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk | Per Zak* |
|---|---|---|
| 1000 + | € 3,672 | € 3.672,00 |
*prijsindicatie
- RS-stocknr.:
- 257-9512
- Fabrikantnummer:
- MA100GG232C
- Fabrikant:
- Amphenol Advanced Sensors
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Amphenol Advanced Sensors | |
| Thermistor Type | NTC | |
| Product Type | NTC Thermistor | |
| Minimum Temperature Sensed | 0°C | |
| Maximum Temperature Sensed | 50°C | |
| Response Time | 2s | |
| Probe Diameter | 2.03mm | |
| Probe Length | 9.52mm | |
| Cable Length | 914mm | |
| Terminal Type | Wire Lead | |
| Accuracy | ±0.15 °C | |
| Material | Polyvinylidene Fluoride | |
| Standards/Approvals | RoHS | |
| Alles selecteren | ||
|---|---|---|
Merk Amphenol Advanced Sensors | ||
Thermistor Type NTC | ||
Product Type NTC Thermistor | ||
Minimum Temperature Sensed 0°C | ||
Maximum Temperature Sensed 50°C | ||
Response Time 2s | ||
Probe Diameter 2.03mm | ||
Probe Length 9.52mm | ||
Cable Length 914mm | ||
Terminal Type Wire Lead | ||
Accuracy ±0.15 °C | ||
Material Polyvinylidene Fluoride | ||
Standards/Approvals RoHS | ||
- Land van herkomst:
- CN
The Amphenol Advanced Sensors thermometrics biomedical chip thermistor assemblies are designed for use in applications involving both intermittent and continuous patient temperature monitoring. Repeatability and fast response are essential, not only for the intermittent temperature requirements associated with oral and rectal fever measurements, but also for the continuous monitoring often necessary during induced-hypothermia and general anaesthesia, or when employed in the care of infants and premature babies.
Intermittent patient temperature monitoring for oral and rectal fever measurements
Continuous patient temperature monitoring during general anaesthesia, induced hypothermia, and premature infant care
Vital sign monitoring for intensive care units and recovery rooms
Temperature monitoring for skin surface, tympanic, oesophageal, foley catheters, and biofeedback