RS PRO Type Type N Thermocouple 2 m Length, 0.3 mm Diameter, -50 °C → 1200 °C Max

Bulkkorting beschikbaar

Subtotaal (1 eenheid)*

€ 9,08

(excl. BTW)

€ 10,99

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 114 stuk(s) klaar voor verzending
  • 215 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.

Aantal stuks
Per stuk
1 - 4€ 9,08
5 - 9€ 8,62
10 +€ 8,18

*prijsindicatie

RS-stocknr.:
621-2192
Artikelnummer Distrelec:
304-17-644
Fabrikant:
RS PRO
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

RS PRO

Thermocouple Type

Type N

Product Type

Thermocouple

Probe Diameter

0.3mm

Probe Length

2m

Maximum Temperature Sensed

1200°C

Terminal Type

Cable

Cable Length

2m

Standards/Approvals

RoHS Compliant

Response Time

0.7s

Minimum Temperature Sensed

-50°C

Land van herkomst:
FR

Features & Benefits


Type N welded tip

2000 mm Length

‐40°C to 375°C ±1.5°C

2 cable 0.07 mm² CSA

RS Pro Glassfibre IEC Exposed Welded Tip Thermocouples


From RS Pro a range of Type J, K, T & N wire type thermocouple temperature sensors conforming to IEC 60584 standards. These thermocouples have a welded exposed hot junction for a fast response time and cable conductors surrounded by a glassfibre insulation.

How does a Thermocouple Work?


A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

What is a Welded Exposed Junction?


An exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures

Properties of Glassfibre Insulation


Glassfibre wire insulation is flexible with a good temperature range but does not prevent the ingress of fluids

Key Features and Benefits


• Welded, exposed junction for fast response times

• Glassfibre insulated cable for good flexibility and temperature range

• Conforms to IEC 60584 standards

Applications


These grounded junction Type J, K, T & N wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications