Littelfuse P0640SCLRP, SIDACtor Protection Thyristor 400 V, 500 A 2.2 mA 35 A 4 V

Subtotaal (1 verpakking van 5 eenheden)*

€ 5,81

(excl. BTW)

€ 7,03

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 2.355 stuk(s) vanaf 30 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
Per verpakking*
5 +€ 1,162€ 5,81

*prijsindicatie

Verpakkingsopties
RS-stocknr.:
171-9665
Fabrikantnummer:
P0640SCLRP
Fabrikant:
Littelfuse
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Littelfuse

Product Type

SIDACtor Protection Thyristor

Rated Average On-State Current Irms

500A

Thyristor Type

SIDACtor

Package Type

DO-214AA

Repetitive Peak Reverse Voltage VDRM

400V

Surge Current Rating

35A

Mount Type

Surface

Maximum Gate Trigger Current Igt

2.2mA

Pin Count

2

Maximum Gate Trigger Voltage Vgt

4V

Maximum Holding Current Ih

150mA

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

150°C

Series

DO-214AA

Standards/Approvals

GR 1089, TIA-968-B, ITU K.20/21/45, Pb-Free, YD/T 950, YD/T 1082, TIA-968-A, IEC 61000-4-5, YD/T 993, RoHS

Repetitive Peak Off-State Current

5μA

Automotive Standard

No

Peak On-State Voltage

4V

Littelfuse DO-214AA SIDACtor solid state protection devices protect telecommunications equipment such as modems, line cards, fax machines, and other CPE.SIDACtor devices are used to enable equipment to meet various regulatory requirements including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA/EIA-IS-968 (formerly known as FCC Part 68).

All measurements are made at an ambient temperature of 25°C. Ipp applies to -40°C through +85°C temperature range.

Ipp is a repetitive surge rating and is guaranteed for the life of the product.

Listed SIDACtor® devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.

Vdrm is measured at Idrm.

Vs is measured at 100 V/μs.

Special voltage (Vs & Vdrm) and holding current (Ih) requirements are available upon request.

Off-state capacitance is measured at 1 MHz with a 2 V bias and is a typical value.

Gerelateerde Links