Idec Plug In Timer Relay, 24V ac/dc, 8-Contact, 0.1 s → 180h, DPDT
- RS-stocknr.:
- 832-5439
- Fabrikantnummer:
- GT3A-3AD24
- Fabrikant:
- Idec
Niet beschikbaar
RS heeft dit product niet meer op voorraad.
- RS-stocknr.:
- 832-5439
- Fabrikantnummer:
- GT3A-3AD24
- Fabrikant:
- Idec
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Idec | |
| Supply Voltage | 24V ac/dc | |
| Mounting Type | Plug In | |
| Mode of Operation | Cycle OFF, Cycle ON, Interval ON, ON Delay | |
| Time Range | 0.1 s → 180h | |
| Number of Contacts | 8 | |
| Number of Timer Functions | Multi Function | |
| Contact Configuration | DPDT | |
| Time Increment | Hours, Minutes, Seconds | |
| Maximum Current | 5A | |
| Switch Configuration | DPDT | |
| Terminal Type | Plug In | |
| Power Supply | External | |
| Width | 40mm | |
| Length | 36mm | |
| Maximum Operating Temperature | +50°C | |
| Depth | 72.2mm | |
| Time Delay | (Reset) 60ms | |
| Minimum Operating Temperature | -10°C | |
| Alles selecteren | ||
|---|---|---|
Merk Idec | ||
Supply Voltage 24V ac/dc | ||
Mounting Type Plug In | ||
Mode of Operation Cycle OFF, Cycle ON, Interval ON, ON Delay | ||
Time Range 0.1 s → 180h | ||
Number of Contacts 8 | ||
Number of Timer Functions Multi Function | ||
Contact Configuration DPDT | ||
Time Increment Hours, Minutes, Seconds | ||
Maximum Current 5A | ||
Switch Configuration DPDT | ||
Terminal Type Plug In | ||
Power Supply External | ||
Width 40mm | ||
Length 36mm | ||
Maximum Operating Temperature +50°C | ||
Depth 72.2mm | ||
Time Delay (Reset) 60ms | ||
Minimum Operating Temperature -10°C | ||
Niet conform
- Land van herkomst:
- TW
The IDEC GT3A series, GT3A-3AD24 is a 8 pin, plug-in, delayed DPDT contact, multi-function timer having 24V AC/24V DC operating voltage. It has time range between 0.1s - 180 hours and output of 240V AC, 24V DC, 5A.
Large variety of timing functions
Power and output status indicating LEDs
Mountable in sockets or flush panels
On Delay, Interval ON, Cycle OFF, Cycle ON
100-240VAC Delayed SPDT 01.s-180h
Power and output status indicating LEDs
Mountable in sockets or flush panels
On Delay, Interval ON, Cycle OFF, Cycle ON
100-240VAC Delayed SPDT 01.s-180h
Gerelateerde Links
- Idec Plug In Timer Relay 11-Contact DPDT
- Idec Plug In Timer Relay 8-Contact SPDT
- RS PRO Plug In Timer Relay 0.1 s → 30min DPDT
- RS PRO Plug In Timer Relay 2-Contact 1-Function, DPDT
- RS PRO Plug In Timer Relay 2-Contact 1-Function, DPDT
- RS PRO Panel Mount Timer Relay 2-Contact DPDT
- Idec Timer Relays
- Omron H3YN Series Panel Mount Timer Relay 4-Contact DPDT