Fluke Networks Pro3000 Tone Generator, 5 Tone, 1000 Hz Tone Frequency

Subtotaal (1 eenheid)*

€ 134,00

(excl. BTW)

€ 162,14

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Beperkte voorraad
  • Plus verzending 13 stuk(s) vanaf 11 mei 2026
  • Plus verzending 38 stuk(s) vanaf 11 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 134,00

*prijsindicatie

RS-stocknr.:
503-568
Artikelnummer Distrelec:
110-42-705
Fabrikantnummer:
Pro3000
Fabrikant:
Fluke Networks
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Fluke Networks

Model Number

Pro3000

Product Type

Tone Generator

Tone Frequency

1000Hz

Number of Tones

5

Power Source

Battery

Battery Type

Alkaline

Standards/Approvals

No

Vrijgesteld

Land van herkomst:
MY

Fluke Tone Generator, 1000Hz Tone Frequency, Alkaline Battery Type - Pro3000


This tone generator is a battery-powered signal source designed to trace and identify communication and cabling pairs in industrial and field environments. It emits selectable cadenced tones to aid pair identification and polarity checks, and is supplied alongside an unfiltered probe with audio monitoring capability for clear cable tracing over long distances.

Features & Benefits


• 1000 Hz nominal solid tone for consistent signal identification
• Alternating 1000/1500 Hz cadence for pair differentiation
• Output 8 dBm into 600 Ω for Detectable signal on long runs
• Continuity mode provides 8V dc output for line verification
• Over-voltage protection at 60V dc for safe connection checks
• 9V alkaline battery operation for field-ready portability

**Applications**


• Suitable for locating faults on twisted-pair network cables
• Ideal for tracing telephone and communication wiring over distance
• Used with probes to confirm pair continuity and polarity
• Can be used for cable routing verification in installations

How many distinct tones are available for pair identification?


Five distinct cadence options are provided so users can change tone patterns by shorting the targeted pair at either end to uniquely mark each pair.

What connection options does the probe provide for audio monitoring?


The probe includes a 3.5mm headphone jack and a volume control allowing direct listening and level adjustment during tracing.

What environmental range supports field operation?


The tools operate between −20 °C and 60 °C and can be stored between −40 °C and 70 °C to suit varied site conditions.

What protection exists when connecting to live lines?


The tone output and polarity functions are safeguarded against voltages up to 60V dc to reduce risk during testing.