Belden 8723LW Series Audio Cable, 2 Pairs, 500 m, Chrome Sheath Low Smoke Zero Halogen
- RS-stocknr.:
- 631-708
- Fabrikantnummer:
- 8723LW.00500
- Fabrikant:
- Belden
Subtotaal (1 rol van 500 meter)*
€ 1.806,12
(excl. BTW)
€ 2.185,41
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 1.806,12 | € 3,612 |
*prijsindicatie
- RS-stocknr.:
- 631-708
- Fabrikantnummer:
- 8723LW.00500
- Fabrikant:
- Belden
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Belden | |
| Number of Pairs | 2 | |
| Product Type | Audio Cable | |
| Cable Length | 500m | |
| Jacket Colour | Chrome | |
| Outside Diameter | 5.6mm | |
| Minimum Operating Temperature | -15°C | |
| Conductor Type | Stranded | |
| Jacket Material | Low Smoke Zero Halogen | |
| Maximum Operating Temperature | 80°C | |
| Standards/Approvals | UKCA, EU, CE | |
| Fire Behaviour | IEC 60332-1-2 | |
| Conductor Material | Tinned Copper | |
| Series | 8723LW | |
| Alles selecteren | ||
|---|---|---|
Merk Belden | ||
Number of Pairs 2 | ||
Product Type Audio Cable | ||
Cable Length 500m | ||
Jacket Colour Chrome | ||
Outside Diameter 5.6mm | ||
Minimum Operating Temperature -15°C | ||
Conductor Type Stranded | ||
Jacket Material Low Smoke Zero Halogen | ||
Maximum Operating Temperature 80°C | ||
Standards/Approvals UKCA, EU, CE | ||
Fire Behaviour IEC 60332-1-2 | ||
Conductor Material Tinned Copper | ||
Series 8723LW | ||
- Land van herkomst:
- NL
Belden 8723LW Series Twisted & Multipair Industrial Cable, 500m Cable Length, Chrome Jacket - 8723LW.00500
This twisted & multipair industrial cable is designed to carry differential signal pairs for industrial communication and control systems. It is intended for use in environments where reduced smoke and halogen-free emissions are required and where consistent signal transmission is needed across a two-pair configuration.
Features & Benefits
• Tinned copper strands improve corrosion resistance and signal integrity
• Stranded conductor 7x30 offers flexibility for routing and installation
• Low Smoke Zero Halogen jacket limits toxic emissions in confined spaces
• Meets IEC60332-1-2 to reduce flame propagation during faults
• Rated for operation up to 80°C to support elevated ambient temperatures
• Chrome-coloured outer sheath provides a durable, identifiable finish
• Stranded conductor 7x30 offers flexibility for routing and installation
• Low Smoke Zero Halogen jacket limits toxic emissions in confined spaces
• Meets IEC60332-1-2 to reduce flame propagation during faults
• Rated for operation up to 80°C to support elevated ambient temperatures
• Chrome-coloured outer sheath provides a durable, identifiable finish
**Applications**
• Suitable for RS485 communications in industrial control networks
• Ideal for industrial Ethernet runs requiring LSZH jacketing
• Used for signal wiring in automation cabinets and field devices
• Can be used for machinery interconnects in manufacturing plants
• Used with building services where low-smoke cables are mandated
• Ideal for industrial Ethernet runs requiring LSZH jacketing
• Used for signal wiring in automation cabinets and field devices
• Can be used for machinery interconnects in manufacturing plants
• Used with building services where low-smoke cables are mandated
What conductor construction aids flexibility during installation?
The cable uses multiple fine tinned copper strands arranged as 7x30 strands per conductor, which enhances bendability and reduces risk of fatigue when pulled through trays or conduits.
How does the outer sheath behave in a fire scenario?
The Low Smoke Zero Halogen material minimises toxic gas output, and the cable has been assessed to the IEC60332-1-2 flame test to limit vertical flame spread.
Which approvals indicate suitability for use across UK and EU projects?
The product carries UKCA and EU CE markings confirming conformity with applicable regulatory requirements for electrical cabling within those markets.
What temperature range can be expected during normal service?
The cable supports continuous use at temperatures up to 80°C and can tolerate installations down to -15°C.
How long is each supplied length and what external size should installers expect?
Each reel contains 500 m of cable and the conductor assembly sits within an overall outside diameter of 5.6 mm.
Gerelateerde Links
- Belden 9729NH Series Audio Cable 500 m Low Smoke Zero Halogen
- Belden 8723NH Series Audio Cable 500 m Low Smoke Zero Halogen
- Belden 8761NH Series Twisted Pair Cable 500 m Low Smoke Zero Halogen
- Belden 9842NH Series Twisted Pair Cable 500 m Low Smoke Zero Halogen
- Belden 9841NH Series Twisted Pair Cable 500 m Low Smoke Zero Halogen
- Belden 8760ELV Series Twisted Pair Cable 500 m Low Smoke Zero Halogen
- Belden 8760NH Series Twisted Pair Cable 500 m Low Smoke Zero Halogen
- Belden 9842LS Series Twisted Pair Cable 500 m Low Smoke Zero Halogen
