Alpha Wire Pro-Tekt Series Data Cable, 5 Pairs, 0.35 mm², 50 m, Grey Sheath Polyvinyl Chloride

Subtotaal (1 rol van 50 meter)*

€ 201,14

(excl. BTW)

€ 243,38

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending 1 stuk(s) vanaf 18 augustus 2026
  • Plus verzending 2 stuk(s) vanaf 01 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 201,14€ 4,023

*prijsindicatie

RS-stocknr.:
740-4840
Fabrikantnummer:
B964052 GE321
Fabrikant:
Alpha Wire
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Alpha Wire

Product Type

Data Cable

Number of Pairs

5

Cross Sectional Area

0.35mm²

Cable Length

50m

Jacket Colour

Grey

Outside Diameter

7.47mm

Jacket Material

Polyvinyl Chloride

Minimum Operating Temperature

-30°C

Conductor Type

Copper

Maximum Operating Temperature

105°C

Standards/Approvals

CE, CSA Certified, UL

Conductor Material

Tin Copper Wire

Series

Pro-Tekt

Voltage

300V

Fire Behaviour

Flame Retardant

Core Strands

7

Belden Pro-Tekt Series Data Cable, 50m Cable Length, 300V Voltage - B964052 GE321


This data cable is a multi-pair communication conductor designed for industrial signal and control wiring in automation, electronics and electrical systems. It combines a grey PVC outer sheath with a cabled assembly of five twisted pairs and an overall foil shield to provide organised pair routing and Basic EMI protection for medium-voltage signal distribution.

Features & Benefits


• 0.35mm2 conductors provide consistent signal-carrying capacity
• 7-strand tinned copper conductors reduce breakage risk
• Flame-retardant construction limits fire propagation
• Rated for -30°C to 105°C operation for varied environments
• 300V voltage rating supports common control systems
• Foil shield and drain support improved noise rejection

**Applications**


• Suitable for factory automation signal and control circuits
• Ideal for industrial panels and instrumentation wiring
• Used with PLCs and distributed I/O networks
• Can be used for machine tool harnessing and cable runs
• Suitable for installations requiring PVC-jacketed multi-pair cable

What conductor make-up ensures flexibility for routing through trays?


Each conductor comprises seven tinned copper strands that give flexibility and mechanical resilience during bending and installation.

How is pair identification handled for termination?


Pairs are colour-coded with white paired to black, brown, red, Orange and yellow to simplify pair selection at termination points.

What shielding arrangement assists with electromagnetic compatibility?


An aluminium/mylar wrap with an internal drain conductor is applied with the foil facing inward to provide a continuous return path and reduce interference.

How is the assembly constructed to maintain pair integrity?


Pairs are cabled together with specified twists per foot and a clear mylar core wrap to preserve geometry and minimise crosstalk.

What physical handling limits should be observed during installation?


The cable has a maximum pull tension of 60 lb and a recommended bend radius of 10x the cable diameter for safe routing.