Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 1 Pairs 4 Cores 1.65 mm² 30 m Slate Sheath PVC
- RS-stocknr.:
- 749-1605
- Fabrikantnummer:
- 6451 SL005
- Fabrikant:
- Alpha Wire
Afbeelding representeert productcategorie
Subtotaal (1 rol van 30 meter)*
€ 375,84
(excl. BTW)
€ 454,77
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 5 stuk(s) vanaf 23 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 375,84 | € 12,528 |
*prijsindicatie
- RS-stocknr.:
- 749-1605
- Fabrikantnummer:
- 6451 SL005
- Fabrikant:
- Alpha Wire
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Alpha Wire | |
| Product Type | Data Cable | |
| Number of Pairs | 1 | |
| Cross Sectional Area | 1.65mm² | |
| Number of Cores | 4 | |
| Cable Length | 30m | |
| Jacket Colour | Slate | |
| Outside Diameter | 12.19mm | |
| Conductor Type | Copper | |
| Minimum Operating Temperature | -20°C | |
| Jacket Material | PVC | |
| Maximum Operating Temperature | 75°C | |
| Standards/Approvals | UL, CSA, CE | |
| Size of Strands | 250μm | |
| Core Strands | 19 x 250 μm | |
| Number of Strands | 19 | |
| Voltage | 300V | |
| Series | Alpha Essentials Data & Bus Cable | |
| Conductor Material | Tin Copper Wire | |
| Fire Behaviour | FT1, VW-1, FT4 | |
| Alles selecteren | ||
|---|---|---|
Merk Alpha Wire | ||
Product Type Data Cable | ||
Number of Pairs 1 | ||
Cross Sectional Area 1.65mm² | ||
Number of Cores 4 | ||
Cable Length 30m | ||
Jacket Colour Slate | ||
Outside Diameter 12.19mm | ||
Conductor Type Copper | ||
Minimum Operating Temperature -20°C | ||
Jacket Material PVC | ||
Maximum Operating Temperature 75°C | ||
Standards/Approvals UL, CSA, CE | ||
Size of Strands 250μm | ||
Core Strands 19 x 250 μm | ||
Number of Strands 19 | ||
Voltage 300V | ||
Series Alpha Essentials Data & Bus Cable | ||
Conductor Material Tin Copper Wire | ||
Fire Behaviour FT1, VW-1, FT4 | ||
Belden Alpha Essentials Data & Bus Cable Series Data Cable, 30m Cable Length, Slate Jacket - 6451 SL005
This data cable is a single-pair transmission cable intended for industrial control and communications environments. It combines a tinned copper conductor assembly with PVC insulation and a slate PVC outer jacket to deliver power and signal capacity for automation and instrumentation systems while operating across common industrial temperature ranges.
Features & Benefits
• 19-strand conductor for enhanced flexibility and fatigue resistance
• 1.65mm² conductor cross section for higher current-carrying capacity
• Rated to 300V for medium-voltage signal and control runs
• Fire behaviour classifications FT1 VW-1 FT4 for improved flame performance
• Temperature range -20°C to 75°C for typical industrial conditions
• UL, CSA, CE approved for recognised standards compliance
• 1.65mm² conductor cross section for higher current-carrying capacity
• Rated to 300V for medium-voltage signal and control runs
• Fire behaviour classifications FT1 VW-1 FT4 for improved flame performance
• Temperature range -20°C to 75°C for typical industrial conditions
• UL, CSA, CE approved for recognised standards compliance
**Applications**
• Suitable for control and signal wiring in automation racks
• Ideal for remote circuit controls in machinery cabinets
• Used for low-voltage circuits in HVAC and building management
• Can be used for telephone or intercom trunking in facilities
• Suitable for data and bus cabling on factory floors
• Ideal for remote circuit controls in machinery cabinets
• Used for low-voltage circuits in HVAC and building management
• Can be used for telephone or intercom trunking in facilities
• Suitable for data and bus cabling on factory floors
What conductor construction aids cable flexibility?
The conductor is a multi-strand tin-plated copper configuration with 19 strands to balance conductivity and repeated-bend performance.
How does the jacket material affect installation?
The PVC outer jacket provides mechanical abrasion resistance and a degree of chemical tolerance while remaining compatible with common cable trays and conduit.
What environmental temperatures can the cable tolerate long term?
The cable is rated to operate continuously down to -20°C and up to 75°C, matching many control-room and panel environments.
Which approvals indicate suitability for international installations?
Listings from UL, CSA and CE indicate that the cable meets widely recognised electrical and safety standards for global use.
Gerelateerde Links
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 4 Pairs 4 Cores 0.2 mm² 30 m Grey Sheath Polyvinyl
- Alpha Wire Ecogen Ecocable Mini Series Data Cable 2 Pairs 4 Cores 0.09 mm² 30 m Slate Sheath MPPE
- Alpha Wire Ecogen Ecocable Mini Series Data Cable 3 Pairs 6 Cores 0.09 mm² 30 m Slate Sheath MPPE
- Alpha Wire Ecogen Ecocable Mini Series Data Cable 2 Pairs 4 Cores 0.241 mm² 30 m Slate Sheath MPPE
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable 2 Pairs 4 Cores 0.56 mm² 305 m Slate Sheath
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable 6 Pairs 12 Cores 0.35 mm² 304 m Slate Sheath
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable 3 Pairs 6 Cores 0.23 mm² 305 m Slate Sheath
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable 1 Pairs 2 Cores 0.81 mm² 305 m Slate Sheath