    Signal conditioners are electronic devices used to modify and optimize electrical signals in various measurement and control systems. They are typically employed in situations where the electrical signals from sensors, transducers, or other sources need to be adjusted or conditioned to meet specific requirements.

    How do Signal Conditioners Work?

    The primary purpose of a signal conditioner is to ensure that the signals are suitable for further processing, transmission, or conversion by other devices or systems. Signal conditioners can perform a variety of functions depending on the specific application.

    What are the types of Signal Conditioning?

    Signal conditioners can be classified into several types based on their specific functions and the signals they process. Here are some common types of signal conditioners: Amplifiers: Amplifiers are signal conditioners used to amplify weak input signals. They increase the signal strength to a level suitable for further processing or transmission. Filters: Signal conditioners that incorporate filters are used to remove unwanted noise or interference from the input signals. Different types of filters, such as low-pass, high-pass, band-pass, or notch filters, are used based on the specific frequency ranges to be filtered. Linearizers: Linearizers are signal conditioners that compensate for nonlinearities in the input signal. They apply mathematical algorithms or lookup tables to linearize the output and provide a more linear response over the measurement range. Isolation Amplifiers: These signal conditioners provide electrical isolation between the input and output sides of a system. They protect sensitive measurement equipment from electrical noise, voltage spikes, and ground loops, ensuring accurate and reliable measurements. Converters: Signal conditioners known as converters are used to convert signals from one form to another. For example, analogue-to-digital converters (ADCs) convert analogue signals into digital form, while digital-to-analogue converters (DACs) convert digital signals into analogue form.

    Where are Signal Conditioners Used?

    Signal conditioners are widely used in industrial automation, process control, data acquisition systems, scientific research, and various other fields where accurate and reliable signal processing is essential. They play a crucial role in optimizing signal quality, reducing noise, and improving the overall performance of measurement and control systems.

    658 Producten voor Signal Conditioners

    Phoenix Contact
    -
    Current Transducer
    Current
    -
    Current
    -
    55A
    0 → 20mA
    20 → 30V dc
    -
    Chassis Mount
    -
    -20°C
    -
    +60°C
    -
    -
    MCR-S10
    Weidmüller
    -
    Signal Converter
    Voltage
    -
    Voltage
    -
    -10 → +10V
    -10 → +10V
    24V dc
    -
    -
    -
    -
    -
    -
    -
    -
    ACT20P
    Weidmüller
    -
    Signal Converter
    Universal
    -
    Universal
    -
    ±40 mV to ±300 V
    0 to ±20mA
    24V dc
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    -
    ACT20P
    Seneca
    -
    Serial Converter
    RS-485
    -
    RS-485
    -
    -
    -
    19.2 → 30V dc
    -
    -
    -
    -
    -
    -
    -
    -
    K-LINE
    WAGO
    -
    Signal Conditioner
    Current, Voltage
    -
    Current, Voltage
    -
    0 → 1kΩ
    0 → 5 V, 0 → 10 V, 1 → 5 V, 2 → 10 V
    24V dc
    -
    DIN Rail
    -
    -25°C
    -25 → +70°C
    +70°C
    -
    -
    857
    Phoenix Contact
    -
    Temperature Converter
    RTD
    -
    Current, Voltage
    -
    0 → 4000 Ω, -200 → +850°C
    0 → 10.5 V, 0 → 24.6mA
    9.6 → 30V dc
    -
    DIN Rail Mount
    -
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    Phoenix Contact
    -
    Voltage Transducer
    Voltage
    -
    Current, Voltage
    -
    0 → 550V ac
    0 → 10 V, 0 → 20mA
    24V dc
    -
    DIN Rail Mount
    -
    -25°C
    -25 → +60°C
    +60°C
    -
    -
    MACX MCR
    Phoenix Contact
    -
    Temperature Converter
    Thermocouple
    -
    Current, Voltage
    -
    -250 → +2500°C
    0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 10 → 0 V, 20 → 0 mA, 20 → 4 mA, 4 → 20mA
    9.6 → 30V dc
    -
    DIN Rail Mount
    -
    -20°C
    -20 → +65°C
    +65°C
    -
    -
    3RS7025
    ifm electronic
    -
    Amplifier
    NPN, PNP
    -
    Relay
    -
    -
    -
    110 → 240V ac
    -
    -
    -
    -
    -
    -
    -
    -
    DN
    Red Lion Controls
    -
    Frequency to Analogue Converter
    -
    -
    Analogue, Relay
    -
    -
    -
    21.6 → 25V ac
    -
    -
    -
    -
    -
    -
    -
    -
    IFM
    Weidmüller
    -
    Signal Converter
    Universal
    -
    Universal
    -
    ±40 mV to ±300 V
    0 to ±20mA
    24V dc
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    -
    ACT20P
    Novotechnik
    -
    Signal Conditioner
    Potentiometer
    -
    Current, Voltage
    -
    -
    0 → 10V
    18-30V dc
    -
    -
    -
    -
    -
    -
    -
    -
    MUP080
    WAGO
    -
    Threshold Value Switch
    RTD, Potentiometer
    -
    Digital, Relay
    -
    -
    -
    -
    -
    DIN Rail Mount
    -
    -
    -
    -
    -
    -
    -
    Phoenix Contact
    -
    Current Transducer
    Current
    -
    Relay
    -
    0 → 16A
    -
    20 → 30V dc
    -
    DIN Rail Mount
    -
    -20°C
    -20 → +65°C
    +65°C
    -
    -
    MCR-VAC
    Phoenix Contact
    -
    Isolation Amplifier
    NAMUR Sensor, Switch
    -
    Transistor
    -
    -
    5kHz
    9.6 → 30V dc
    -
    DIN Rail Mount
    -
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    Phoenix Contact
    -
    Voltage Transducer
    Voltage
    -
    Current, Voltage
    -
    -550 → +550V dc
    -10 → 10 V, -20 mA → 20mA
    24V dc
    -
    DIN Rail Mount
    -
    -25°C
    -25 → +60°C
    +60°C
    -
    -
    MACX MCR
    Phoenix Contact
    -
    Resistance/Potiposition Transducer
    Resistance
    -
    Current, Voltage
    -
    100 Ω → 100kΩ
    0 → 12.3 V, 0 → 24.6mA
    9.6 → 30V dc
    -
    DIN Rail Mount
    -
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    Murrelektronik Limited
    -
    Proportional Amplifier
    Voltage
    -
    Current, Voltage
    -
    18 → 32V dc
    24 V dc, 0.02 → 2.5A
    18 → 32V dc
    -
    DIN Rail Mount
    -
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    -
    Phoenix Contact
    -
    Isolation Amplifier
    Current, Voltage
    -
    Current
    -
    0 → 10 V, 0 → 20mA
    0 → 20mA
    24V dc
    ATEX
    DIN Rail Mount
    -
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    3RS7003
    Phoenix Contact
    -
    Isolation Amplifier
    Voltage
    -
    Current, Voltage
    -
    -1 → 3 V, -800 → 800mV
    0 → 10 V, 0 → 20mA
    19.2 → 30V dc
    -
    DIN Rail Mount
    -
    -20°C
    -20 → +65°C
    +65°C
    -
    -
    MACX
    Resultaten per pagina