Schneider Electric 24V ac/dc DIN Rail Circuit Trip for use with IDPN Vigi, RCA, IlD MCB, Ild Double Terminal, ISW-NA,
- RS-stocknr.:
- 791-2812
- Fabrikantnummer:
- A9A26948
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 70,24
(excl. BTW)
€ 84,99
(incl. BTW)
Voeg 2 eenheden toe voor gratis bezorging
Op voorraad
- 29 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 70,24 |
*prijsindicatie
- RS-stocknr.:
- 791-2812
- Fabrikantnummer:
- A9A26948
- Fabrikant:
- Schneider Electric
Datasheets
Wetgeving en compliance
Productomschrijving
Schneider Electric Shunt Release Trip, 12 To 24V AC/DC - Acti9 Series - A9A26948
Add a final level of protection to your electrical distribution system with this shunt trip from Schneider Electric. The shunt trip instantly opens a residual circuit breaker for immediate tripping in the event of a power fault. Its emergency stopping function offers enhanced protection for people and equipment against electrical hazards, such as short circuits, earth leakages and current overloads. The modular device is easily clipped onto a DIN rail and features a small footprint to reduce bulk in your control panel.
Features & Benefits
• Environmentally friendly product that's largely recyclable
• Contains no toxic heavy metals for improved operator health and workplace safety
• Wide operating temperature range of -40°C to +85°C for use in demanding industrial environments
• Prevents uncontrolled starting of machinery for increased safety levels in the workplace
Applications
• Starter-motor control systems
• Conveyors
• Marine and offshore industries
Does this shunt trip draw power from the circuit breaker it's protecting?
No, this shunt trip is powered from an external source to ensure it operates independently of the circuit breaker.
Do I have to use a shunt trip in conjunction with a circuit breaker?
No, you don't. It's an optional device that acts as a supplement to the mains protection unit.
Gerelateerde Links
- Schneider Electric DIN Rail Shunt Trip for use with Ild Double Terminal RCA iC60 MCB IDPN Vigi
- Schneider Electric 415V DIN Rail Circuit Trip for use with Ild Double Terminal RCA IDPN Vigi
- Schneider Electric 24V DIN Rail Shunt Trip for use with Ild Double Terminal ARA IlD MCB iC60
- Schneider Electric DIN Rail Circuit Trip for use with ISW-NA RCA Ild Double Terminal
- Schneider Electric Acti 9 Cover for use with ARA iDPN Vigi iSW RCA, Reflex iC60
- Schneider Electric Acti 9 Plug-in Base for use with ARA iDPN Vigi ISW RCA, Reflex iC60
- Schneider Electric Acti 9 Inter-Pole Barrier for use with ARA iDPN Vigi ISW RCA, Reflex iC60
- Schneider Electric 48V ac/dc Shunt Trip Shunt trip for use with ARA IDPN Vigi ilD MCB,