Schneider Electric, TeSyS LR Thermal Overload Relay 1 NO/1 NC, Trip Dial: 1.2 → 1.8 A, 1.2A, 1.8 A F.L.C, 1.8A Contact
- RS-stocknr.:
- 758-945
- Artikelnummer Distrelec:
- 301-12-063
- Fabrikantnummer:
- LR2K0307
- Fabrikant:
- Schneider Electric
Voeg 10 meer toe om 4% te besparen
Bekijk bulkkortingSubtotaal (1 eenheid)*
€ 52,54
(excl. BTW)
€ 63,57
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 10 stuk(s) klaar voor verzending
- 55 stuk(s) klaar voor verzending vanaf een andere locatie
Aantal stuks | Per stuk | Bespaar |
|---|---|---|
| 1 - 9 | € 52,54 | - |
| 10 - 14 | € 50,39 | 4% |
| 15 + | € 48,23 | 8% |
*prijsindicatie
- RS-stocknr.:
- 758-945
- Artikelnummer Distrelec:
- 301-12-063
- Fabrikantnummer:
- LR2K0307
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Thermal Overload Relay | |
| FLC Motor Rating | 1.2A, 1.8A | |
| Relay Contact Current | 1.8A | |
| Series | TeSyS LR | |
| Mount Type | Under Contactor | |
| Power Rating | 100W | |
| Pole and Throw Configuration | 3 | |
| Terminal Type | Screw | |
| Normal State Configuration | 1 NO/1 NC | |
| Reset Method | Automatic & Manual | |
| IP Rating | IP2X | |
| Number of Auxiliary Contacts | 2 | |
| Adjustable Current Range | 1.2 → 1.8 A | |
| Minimum Operating Temperature | -20°C | |
| Width | 45mm | |
| Contact Voltage | 690V ac | |
| Maximum Operating Temperature | 55°C | |
| Length | 116mm | |
| Standards/Approvals | CSA/IEC 60947, NFC 63-650, UKCA, VDE 0660, BS 4941, UL | |
| Depth | 65mm | |
| Control Voltage | 250V dc, 690V dc | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Thermal Overload Relay | ||
FLC Motor Rating 1.2A, 1.8A | ||
Relay Contact Current 1.8A | ||
Series TeSyS LR | ||
Mount Type Under Contactor | ||
Power Rating 100W | ||
Pole and Throw Configuration 3 | ||
Terminal Type Screw | ||
Normal State Configuration 1 NO/1 NC | ||
Reset Method Automatic & Manual | ||
IP Rating IP2X | ||
Number of Auxiliary Contacts 2 | ||
Adjustable Current Range 1.2 → 1.8 A | ||
Minimum Operating Temperature -20°C | ||
Width 45mm | ||
Contact Voltage 690V ac | ||
Maximum Operating Temperature 55°C | ||
Length 116mm | ||
Standards/Approvals CSA/IEC 60947, NFC 63-650, UKCA, VDE 0660, BS 4941, UL | ||
Depth 65mm | ||
Control Voltage 250V dc, 690V dc | ||
Vrijgesteld
- Land van herkomst:
- CZ
Schneider Electric LR2K Series Thermal Overload Relay, 1.8A Contact Current Rating, 100W - LR2K0307
Features & Benefits
Applications
Can it be used with solid and flexible cables?
Will it provide indication when tripped?
Is it suitable for high voltage systems?
Can the reset method be altered?
Does it comply with international standards?
Gerelateerde Links
- Schneider Electric Trip Dial: 0.8 → 1.2 A 1.2A F.L.C, 1.2A Contact
- Omron Trip Dial: 23 → 32 A 1.8 A F.L.C 15 kW 3P
- WEG Trip Dial: 1.2 → 1.8 A 1.2A 1.4 W 3
- WEG Trip Dial: 1.2 → 1.8 A 1.2A 1.7 W 3
- Omron Trip Dial: 1.2 → 1.8 A 2.7 A F.L.C, 2.7A Contact Rating 3P
- Siemens Trip Dial: 1.8 → 2.5 A 2.5 A F.L.C
- Schneider Electric Trip Dial: 90 → 150 A 32V 3
- Allen Bradley Trip Dial: 1.8 → 2.7 A 2.5 A F.L.C 6 W, 690V