Schneider Electric, TeSyS LR Thermal Overload Relay 1 NO/1 NC, 1.2A, 1.8 A F.L.C, 1.8A Contact Rating, 100 W, 250 V dc,
- RS-stocknr.:
- 758-945
- Artikelnummer Distrelec:
- 301-12-063
- Fabrikantnummer:
- LR2K0307
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 52,54
(excl. BTW)
€ 63,57
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- Plus verzending 5 stuk(s) vanaf 14 september 2026
- Plus verzending 100 stuk(s) vanaf 14 september 2026
Aantal stuks | Per stuk |
|---|---|
| 1 - 9 | € 52,54 |
| 10 - 14 | € 50,39 |
| 15 + | € 48,23 |
*prijsindicatie
- RS-stocknr.:
- 758-945
- Artikelnummer Distrelec:
- 301-12-063
- Fabrikantnummer:
- LR2K0307
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| FLC Motor Rating | 1.2, 1.8A | |
| Product Type | Thermal Overload Relay | |
| Relay Contact Current | 1.8A | |
| Mount Type | DIN Rail | |
| Series | TeSyS LR | |
| Power Rating | 100W | |
| Pole and Throw Configuration | 3 | |
| Normal State Configuration | 1 NO/1 NC | |
| Terminal Type | Screw | |
| Reset Method | Automatic & Manual | |
| IP Rating | IP2X | |
| Width | 45mm | |
| Number of Auxiliary Contacts | 2 | |
| Adjustable Current Range | 1.2 → 1.8 A | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 55°C | |
| Contact Voltage | 690V ac | |
| Length | 116mm | |
| Depth | 65mm | |
| Standards/Approvals | CSA/IEC 60947, NFC 63-650, UKCA, VDE 0660, BS 4941, UL | |
| Control Voltage | 250, 690V dc | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
FLC Motor Rating 1.2, 1.8A | ||
Product Type Thermal Overload Relay | ||
Relay Contact Current 1.8A | ||
Mount Type DIN Rail | ||
Series TeSyS LR | ||
Power Rating 100W | ||
Pole and Throw Configuration 3 | ||
Normal State Configuration 1 NO/1 NC | ||
Terminal Type Screw | ||
Reset Method Automatic & Manual | ||
IP Rating IP2X | ||
Width 45mm | ||
Number of Auxiliary Contacts 2 | ||
Adjustable Current Range 1.2 → 1.8 A | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 55°C | ||
Contact Voltage 690V ac | ||
Length 116mm | ||
Depth 65mm | ||
Standards/Approvals CSA/IEC 60947, NFC 63-650, UKCA, VDE 0660, BS 4941, UL | ||
Control Voltage 250, 690V dc | ||
Vrijgesteld
- Land van herkomst:
- CZ
Schneider Electric LR2K Series Thermal Overload Relay, 1.8A Contact Current Rating, 100W - LR2K0307
Features & Benefits
Applications
Can it be used with solid and flexible cables?
Will it provide indication when tripped?
Is it suitable for high voltage systems?
Can the reset method be altered?
Does it comply with international standards?
Gerelateerde Links
- Omron 1.2A 1.8A Contact Rating, 15 kW 3P
- WEG 1.8A F.L.C 1.8 A Contact Rating, 1.4 W 3
- WEG 1.8A F.L.C 1.8 A Contact Rating, 1.7 W 3
- Schneider Electric 0.8A 1.2A Contact Rating 250 V dc, 690V
- Omron 1.8A 2.7A Contact Rating 3P
- Omron 1.8A 2.7A Contact Rating, 15 kW 3P
- Omron 0.8A 1.2A Contact Rating, 24V dc 3P
- Siemens 1.8A 2.5A Contact Rating, 1.5 kW 3P