Schneider Electric, TeSyS LR Overload Relay 1 NO/1 NC, 2.5A, 4 A F.L.C, 4A Contact Rating, 1.5 kW 3
- RS-stocknr.:
- 394-9380
- Artikelnummer Distrelec:
- 136-22-707
- Fabrikantnummer:
- LRD08
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 65,18
(excl. BTW)
€ 78,87
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 3 stuk(s) klaar voor verzending
- 184 stuk(s) klaar voor verzending vanaf een andere locatie
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 65,18 |
*prijsindicatie
- RS-stocknr.:
- 394-9380
- Artikelnummer Distrelec:
- 136-22-707
- Fabrikantnummer:
- LRD08
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| FLC Motor Rating | 2.5, 4A | |
| Product Type | Overload Relay | |
| Relay Contact Current | 4A | |
| Mount Type | Direct | |
| Series | TeSyS LR | |
| Pole and Throw Configuration | 3 | |
| Power Rating | 1.5kW | |
| Terminal Type | Screw | |
| Normal State Configuration | 1 NO/1 NC | |
| IP Rating | IP20 | |
| Reset Method | Automatic & Manual | |
| Minimum Operating Temperature | -20°C | |
| Number of Auxiliary Contacts | 2 | |
| Width | 45mm | |
| Adjustable Current Range | 2.5 → 4 A | |
| Maximum Operating Temperature | 60°C | |
| Contact Voltage | 690V ac | |
| Length | 123mm | |
| Depth | 66mm | |
| Standards/Approvals | UL Approved, UL 60947-5-1, UL 60947-4-1, EN/IEC 60947-5-1, EN/IEC 60947-4-1, EC Approved, EAC Approved, DNV-GL Approved, CSA C22.2 No 60947-5-1, CSA C22.2 No 60947-4-1, CSA Approved | |
| Supply Voltage | 690V | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
FLC Motor Rating 2.5, 4A | ||
Product Type Overload Relay | ||
Relay Contact Current 4A | ||
Mount Type Direct | ||
Series TeSyS LR | ||
Pole and Throw Configuration 3 | ||
Power Rating 1.5kW | ||
Terminal Type Screw | ||
Normal State Configuration 1 NO/1 NC | ||
IP Rating IP20 | ||
Reset Method Automatic & Manual | ||
Minimum Operating Temperature -20°C | ||
Number of Auxiliary Contacts 2 | ||
Width 45mm | ||
Adjustable Current Range 2.5 → 4 A | ||
Maximum Operating Temperature 60°C | ||
Contact Voltage 690V ac | ||
Length 123mm | ||
Depth 66mm | ||
Standards/Approvals UL Approved, UL 60947-5-1, UL 60947-4-1, EN/IEC 60947-5-1, EN/IEC 60947-4-1, EC Approved, EAC Approved, DNV-GL Approved, CSA C22.2 No 60947-5-1, CSA C22.2 No 60947-4-1, CSA Approved | ||
Supply Voltage 690V | ||
Vrijgesteld
- Land van herkomst:
- FR
Schneider Electric LRD Series Overload Relay, 2.5 to 4A FLC Motor Rating, 4A Contact Current Rating - LRD08
Features & Benefits
Applications
How does the tripping mechanism work during motor overload situations?
What type of connections are supported for control circuits?
What are the implications of its IP20 rating?
How can temperature variations affect the performance of this relay?
What is the benefit of using multiple auxiliary contacts?
Gerelateerde Links
- Schneider Electric 2.5A 4A Contact Rating 600V 3
- Schneider Electric 4A 5A Contact Rating
- Schneider Electric 4A 5A Contact Rating
- Schneider Electric 4A F.L.C 690V ac
- Schneider Electric 1.6A 2.5A Contact Rating, 0.75 kW 3
- Schneider Electric 4A F.L.C 690V ac 3
- Schneider Electric 2.5A F.L.C 0.75 kW, 690V ac 3
- Schneider Electric 1.6A 2.5A Contact Rating, 0.75 kW 3