Schneider Electric, LRD Overload Relay 1 NO/1 NC, Trip Dial: 2.5 → 4 A, 2.5A, 4 A F.L.C, 4A Contact Rating, 1.5 kW 3
- RS-stocknr.:
- 394-9380
- Artikelnummer Distrelec:
- 136-22-707
- Fabrikantnummer:
- LRD08
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 65,18
(excl. BTW)
€ 78,87
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- Plus verzending 8 stuk(s) vanaf 12 oktober 2026
- Plus verzending 232 stuk(s) vanaf 12 oktober 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 65,18 |
*prijsindicatie
- RS-stocknr.:
- 394-9380
- Artikelnummer Distrelec:
- 136-22-707
- Fabrikantnummer:
- LRD08
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Product Type | Overload Relay | |
| FLC Motor Rating | 2.5A, 4A | |
| Relay Contact Current | 4A | |
| Mount Type | Direct | |
| Series | LRD | |
| Pole and Throw Configuration | 3 | |
| Power Rating | 1.5kW | |
| Normal State Configuration | 1 NO/1 NC | |
| Terminal Type | Screw | |
| Reset Method | Automatic & Manual | |
| IP Rating | IP20 | |
| Number of Auxiliary Contacts | 2 | |
| Width | 45mm | |
| Minimum Operating Temperature | -20°C | |
| Adjustable Current Range | 2.5 → 4 A | |
| Maximum Operating Temperature | 60°C | |
| Contact Voltage | 690V ac | |
| Length | 66mm | |
| Standards/Approvals | UL Approved, UL 60947-5-1, UL 60947-4-1, EN/IEC 60947-5-1, EN/IEC 60947-4-1, EC Approved, EAC Approved, DNV-GL Approved, CSA C22.2 No 60947-5-1, CSA C22.2 No 60947-4-1, CSA Approved | |
| Depth | 70mm | |
| Supply Voltage | 690V | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Product Type Overload Relay | ||
FLC Motor Rating 2.5A, 4A | ||
Relay Contact Current 4A | ||
Mount Type Direct | ||
Series LRD | ||
Pole and Throw Configuration 3 | ||
Power Rating 1.5kW | ||
Normal State Configuration 1 NO/1 NC | ||
Terminal Type Screw | ||
Reset Method Automatic & Manual | ||
IP Rating IP20 | ||
Number of Auxiliary Contacts 2 | ||
Width 45mm | ||
Minimum Operating Temperature -20°C | ||
Adjustable Current Range 2.5 → 4 A | ||
Maximum Operating Temperature 60°C | ||
Contact Voltage 690V ac | ||
Length 66mm | ||
Standards/Approvals UL Approved, UL 60947-5-1, UL 60947-4-1, EN/IEC 60947-5-1, EN/IEC 60947-4-1, EC Approved, EAC Approved, DNV-GL Approved, CSA C22.2 No 60947-5-1, CSA C22.2 No 60947-4-1, CSA Approved | ||
Depth 70mm | ||
Supply Voltage 690V | ||
Vrijgesteld
- Land van herkomst:
- FR
Schneider Electric LRD Series Overload Relay, 2.5 to 4A FLC Motor Rating, 4A Contact Current Rating - LRD08
Features & Benefits
Applications
How does the tripping mechanism work during motor overload situations?
What type of connections are supported for control circuits?
What are the implications of its IP20 rating?
How can temperature variations affect the performance of this relay?
What is the benefit of using multiple auxiliary contacts?
Gerelateerde Links
- Schneider Electric 1.6A 2.5A Contact Rating, 750 W 3
- Lovato 2.5A 4A Contact Rating 3
- Schneider Electric 4A 6A Contact Rating, 2.2 kW 3
- Schneider Electric 2.5A 4A Contact Rating 600V 3
- Siemens 2.5A F.L.C 0.75 kW, 690V
- Schneider Electric 17A 25A Contact Rating
- Siemens 4A F.L.C 0.1 W 3P
- Siemens 4A F.L.C 3 kW, 230V 3P