Schneider Electric, LRD Overload Relay 1 NO/1 NC, Trip Dial: 1 → 1.7 A, 1A, 1.6 A F.L.C, 1.6A Contact Rating, 550 W 3
- RS-stocknr.:
- 394-9419
- Artikelnummer Distrelec:
- 136-22-705
- Fabrikantnummer:
- LRD06
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 65,18
(excl. BTW)
€ 78,87
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 18 stuk(s) klaar voor verzending
- 84 stuk(s) klaar voor verzending vanaf een andere locatie
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 65,18 |
*prijsindicatie
- RS-stocknr.:
- 394-9419
- Artikelnummer Distrelec:
- 136-22-705
- Fabrikantnummer:
- LRD06
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| FLC Motor Rating | 1A, 1.6A | |
| Product Type | Overload Relay | |
| Relay Contact Current | 1.6A | |
| Series | LRD | |
| Mount Type | Direct | |
| Pole and Throw Configuration | 3 | |
| Power Rating | 550W | |
| Normal State Configuration | 1 NO/1 NC | |
| Terminal Type | Screw | |
| IP Rating | IP20 | |
| Reset Method | Automatic & Manual | |
| Adjustable Current Range | 1 → 1.7 A | |
| Number of Auxiliary Contacts | 2 | |
| Minimum Operating Temperature | -20°C | |
| Width | 45mm | |
| Length | 66mm | |
| Contact Voltage | 690V ac | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | CSA Approved, UL Approved, UL 60947-5-1, UL 60947-4-1, EN/IEC 60947-5-1, EN/IEC 60947-4-1, CSA C22.2 No 60947-4-1, EAC Approved, EC Approved, DNV-GL Approved, CSA C22.2 No 60947-5-1 | |
| Depth | 70mm | |
| Supply Voltage | 690V ac | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
FLC Motor Rating 1A, 1.6A | ||
Product Type Overload Relay | ||
Relay Contact Current 1.6A | ||
Series LRD | ||
Mount Type Direct | ||
Pole and Throw Configuration 3 | ||
Power Rating 550W | ||
Normal State Configuration 1 NO/1 NC | ||
Terminal Type Screw | ||
IP Rating IP20 | ||
Reset Method Automatic & Manual | ||
Adjustable Current Range 1 → 1.7 A | ||
Number of Auxiliary Contacts 2 | ||
Minimum Operating Temperature -20°C | ||
Width 45mm | ||
Length 66mm | ||
Contact Voltage 690V ac | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals CSA Approved, UL Approved, UL 60947-5-1, UL 60947-4-1, EN/IEC 60947-5-1, EN/IEC 60947-4-1, CSA C22.2 No 60947-4-1, EAC Approved, EC Approved, DNV-GL Approved, CSA C22.2 No 60947-5-1 | ||
Depth 70mm | ||
Supply Voltage 690V ac | ||
Vrijgesteld
- Land van herkomst:
- FR
Schneider Electric LRD Series Overload Relay, 1.6A Contact Current Rating, 3P Pole Configuration - LRD06
Features & Benefits
Applications
How does the automatic reset function enhance usability?
What is the purpose of the 1NO + 1NC configuration?
What is the significance of the thermal overload class 10A?
How can this overload relay manage high operational temperatures?
What benefit does the screw clamp terminal provide?
Gerelateerde Links
- Schneider Electric Trip Dial: 1.6 → 2.5 A 2.5 A F.L.C 750 W
- Siemens Trip Dial: 1.1 → 1.6 A 1.6A Contact Rating
- Siemens Trip Dial: 1.1 → 1.6 A 1.6A Contact Rating
- Schneider Electric Trip Dial: 0.16 → 0.25 A 250 mA F.L.C
- Schneider Electric Trip Dial: 0.25 → 0.4 A 400 mA F.L.C, 400mA Contact
- Schneider Electric Trip Dial: 17 → 25 A 25 A F.L.C, 25A Contact Rating
- Schneider Electric Trip Dial: 0.4 → 0.63 A 630 mA F.L.C
- ABB Thermal Overload Relay 1 NO/1 NC 1.3A 1.7A Contact Rating, 600V dc 3
