ABB NFZB..RT Contactor Relay, 130 V dc Coil, 4-Pole, 6 A, 0.14 kW 690 V, 4 NO/4 NC, 690V
- RS-stocknr.:
- 237-4875
- Fabrikantnummer:
- 1SBH136060R2244
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 134,55
(excl. BTW)
€ 162,81
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 09 april 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 134,55 |
*prijsindicatie
- RS-stocknr.:
- 237-4875
- Fabrikantnummer:
- 1SBH136060R2244
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Contactor Relay | |
| Coil Voltage | 130 V dc | |
| Number of Poles | 4 | |
| Contact Voltage | 690V | |
| Contact Current | 6A | |
| Series | NFZB..RT | |
| Power Rating | 0.14kW | |
| Normal State Configuration | 4 NO/4 NC | |
| Auxiliary Contact Configuration | 4 pole | |
| Number of Auxiliary Contacts | 8 | |
| Terminal Type | Ring Tongue Terminal | |
| Control Circuit Voltage Uc | 690 V | |
| Operational Current Ie | 6A | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 70°C | |
| Depth | 86mm | |
| Standards/Approvals | CB, CCC, CQC, CSA C22.2 No. 60947-5-1, EAC, EN 50155, IEC 60077-1, IEC 60077-2, IEC 61373, IEC/EN 60947-1, IEC/EN 60947-5-1, RoHS, TR CU 001/2011, UL, UL 60947-5-1 | |
| Width | 45 mm | |
| Length | 86mm | |
| Pole and Throw Configuration | 8 | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Contactor Relay | ||
Coil Voltage 130 V dc | ||
Number of Poles 4 | ||
Contact Voltage 690V | ||
Contact Current 6A | ||
Series NFZB..RT | ||
Power Rating 0.14kW | ||
Normal State Configuration 4 NO/4 NC | ||
Auxiliary Contact Configuration 4 pole | ||
Number of Auxiliary Contacts 8 | ||
Terminal Type Ring Tongue Terminal | ||
Control Circuit Voltage Uc 690 V | ||
Operational Current Ie 6A | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 70°C | ||
Depth 86mm | ||
Standards/Approvals CB, CCC, CQC, CSA C22.2 No. 60947-5-1, EAC, EN 50155, IEC 60077-1, IEC 60077-2, IEC 61373, IEC/EN 60947-1, IEC/EN 60947-5-1, RoHS, TR CU 001/2011, UL, UL 60947-5-1 | ||
Width 45 mm | ||
Length 86mm | ||
Pole and Throw Configuration 8 | ||
- Land van herkomst:
- FR
ABB NFZ Series Contactor Relay, 8 Poles, 130V Coil Voltage - 1SBH136060R2244
This contactor relay is specifically designed for high-performance applications in railway environments. Complying with the latest standards, it features a compact design with dimensions of 86mm x 45mm x 86mm, suitable for installation in restricted spaces. The unit operates efficiently within a control voltage range of 48V to 130V and functions seamlessly in temperatures ranging from -40°C to +70°C.
Features & Benefits
• Comprises 4 normally open and 4 normally closed contacts
• Supports 6A contact current rating for reliable operation
• Mounts easily on DIN rails, simplifying installation
• Utilises ring tongue terminals for secure cable connections
• Designed for reduced energy use, consuming 68% less during operation
• Compliant with fire and smoke behaviour standards for railway safety
Applications
• Used in switching auxiliary and control circuits in trains
• Suitable for installations in passenger and driver cabins
• Employed in environments with high vibration and shock requirements
• Ideal for requiring compact device solutions
What is the maximum voltage this device can handle in auxiliary circuits?
It can handle a rated operational voltage of 690V in auxiliary circuits, ensuring reliable performance in demanding conditions.
How does the relay manage thermal conditions during operation?
The relay effectively operates within a temperature range of -40°C to +70°C while maintaining functionality, which is crucial for varying environmental conditions.
What type of connections can be used with this relay?
It accepts ring tongue ferrules, with non-detachable screws providing secure and stable connections for the auxiliary terminals.
What are the rated control voltage specifications?
The rated control circuit voltage operates between 48V and 130V, making it versatile for various applications within specified limits.
How does the design improve energy efficiency for trains?
The relay's design reduces train energy consumption by requiring significantly less coil energy during operation, achieving a reduction of 68%.
Gerelateerde Links
- ABB NFZB..RT Contactor Relay 4-Pole 0.14 kW 690 V 690V
- ABB NFZB..RT Contactor Relay 4-Pole 0.14 kW 690 V 690V
- ABB NFZB..RT Contactor Relay 4-Pole 0.14 kW 690 V 690V
- ABB NFZB..RT Contactor Relay 4-Pole 0.14 kW 690 V 690V
- ABB NFZ40E-22 Contactor Relay 4-Pole 0.14 kW 48 to 130 V 690V
- ABB NFZ Contactor Relay 8-Pole 0.14 kW 690 V 690V
- ABB NF Contactor Relay 4-Pole 0.14 kW 690 V 690V
- ABB AF Range Contactor Relay 4-Pole 690 V 690V