ABB 1SBL18 Contactor, 230V, 240 V Coil, 3-Pole, 16 A 230V, 240 V, 3 NO, 690V
- RS-stocknr.:
- 253-1940
- Fabrikantnummer:
- 1SBL181022R8810
- Fabrikant:
- ABB
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 253-1940
- Fabrikantnummer:
- 1SBL181022R8810
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Coil Voltage | 230V, 240V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 16A | |
| Series | 1SBL18 | |
| Function | Control Unit | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 3 NO | |
| Auxiliary Contact Configuration | 1 NO | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Control Circuit Voltage Uc | 230V, 240V | |
| Contactor Application | Control Unit | |
| Minimum Operating Temperature | -40°C | |
| Operational Current Ie | 16A | |
| Maximum Operating Temperature | 55°C | |
| Length | 74mm | |
| Width | 44mm | |
| Standards/Approvals | IEC 60068-2-11, IEC 60068-2-30, IEC 60529, IEC 60947-4-1, IEC 60947-5-1 | |
| Depth | 74mm | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Coil Voltage 230V, 240V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 16A | ||
Series 1SBL18 | ||
Function Control Unit | ||
Mount Type DIN Rail | ||
Normal State Configuration 3 NO | ||
Auxiliary Contact Configuration 1 NO | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Control Circuit Voltage Uc 230V, 240V | ||
Contactor Application Control Unit | ||
Minimum Operating Temperature -40°C | ||
Operational Current Ie 16A | ||
Maximum Operating Temperature 55°C | ||
Length 74mm | ||
Width 44mm | ||
Standards/Approvals IEC 60068-2-11, IEC 60068-2-30, IEC 60529, IEC 60947-4-1, IEC 60947-5-1 | ||
Depth 74mm | ||
Pole and Throw Configuration 3P | ||
- Land van herkomst:
- BG
ABB UA16 Series Contactor, 16A Operational Current, 230 to 240V Control Circuit Voltage - 1SBL181022R8810
This contractor is a compact, three-pole control unit designed for switching capacitor banks in industrial control installations. It operates from a 230/240V AC control circuit and is configured with three main normally open poles and one built-in auxiliary contact, providing focused functionality for capacitor switching where inrush peaks comply with the devices limits.
Features & Benefits
• Rated operational current 16A enabling moderate load switching
• Supports capacitor switching with Peak inrush allowance up to 100x nominal
• Coil rated 230 to 240V for compatibility with common control supplies
• Screw terminals simplify secure connections and cable clamp fixing
• DIN rail mounting for efficient panel installation and space saving
• Electrical durability of 100000 operating cycles under specified conditions
• Supports capacitor switching with Peak inrush allowance up to 100x nominal
• Coil rated 230 to 240V for compatibility with common control supplies
• Screw terminals simplify secure connections and cable clamp fixing
• DIN rail mounting for efficient panel installation and space saving
• Electrical durability of 100000 operating cycles under specified conditions
Applications
• Suitable for switching capacitor banks in reactive power compensation panels
• Used for control of motor-starting reactive circuits with limited inrush
• Ideal for integration into automation panels requiring DIN rail components
• Suitable for installers needing a Compact 3-pole contactor for retrofit
• Used for control of motor-starting reactive circuits with limited inrush
• Ideal for integration into automation panels requiring DIN rail components
• Suitable for installers needing a Compact 3-pole contactor for retrofit
What ambient temperatures can it tolerate during operation?
It can operate in free Air between -40°C and +55°C when supplied at 0.85 to 1.1Uc and up to +70°C at rated Uc under specified conditions.
How is the unit protected against electrical transients?
The device has a rated insulation voltage of 1000V and an impulse withstand capability of 8kV to withstand transient stress.
What are the connection capacities for main and auxiliary circuits?
Main and auxiliary circuits accept flexible cable with ferrules from 0.75 to 2.5mm² and rigid conductors from 1 to 4mm².
How fast does it respond electrically when energised or de-energised?
Typical operate times are 10 to 26ms for Coil energisation to contact closing and 4 to 11ms for release to NO contact opening.
Which protective device ratings are recommended for short-circuit protection?
Use gG type fuses 1.5 to 1.8A for certain circuits and 10A for the auxiliary protection as indicated by the devices protection guidance.
Gerelateerde Links
- ABB 1SBL18 Contactor 240 V Coil 16 A 230V 3 NO, 690V
- ABB 1SBL2 Contactor 240 V Coil 4 A 230V 4 NO, 690V
- ABB 1SBL41 Contactor 260 V Coil 240 V 690V
- ABB 1SBL37 Contactor 260 V Coil 240 V 690V
- ABB 1SBL18 Contactor 400 V Coil 16 A 400V 3 NO, 690V
- ABB 1SBL18 Contactor 3-Pole 3 NO, 690V
- ABB 1SBL28 Contactor 260 V Coil 4 A 230V 3 NO, 690V
- ABB 1SBL18 Contactor 230 V Coil 16 A 220V 4 NO, 690V