ABB 1SBL24 Contactor, 110V, 120 V Coil, 3-Pole, 6 A 110V, 3 NO, 690V
- RS-stocknr.:
- 253-1961
- Fabrikantnummer:
- 1SBL241022R8410
- Fabrikant:
- ABB
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 253-1961
- Fabrikantnummer:
- 1SBL241022R8410
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Coil Voltage | 110V, 120V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 6A | |
| Series | 1SBL24 | |
| Mount Type | DIN Rail | |
| Function | Control Unit | |
| Normal State Configuration | 3 NO | |
| Auxiliary Contact Configuration | 1 NO | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 110V | |
| Minimum Operating Temperature | -40°C | |
| Operational Current Ie | 6A | |
| Maximum Operating Temperature | 70°C | |
| Depth | 90mm | |
| Standards/Approvals | EU 2011/65/EU, IEC 60068-2-30 and 60068-2-11, UTE C 63-100 specification II | |
| Width | 54mm | |
| Length | 94mm | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Coil Voltage 110V, 120V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 6A | ||
Series 1SBL24 | ||
Mount Type DIN Rail | ||
Function Control Unit | ||
Normal State Configuration 3 NO | ||
Auxiliary Contact Configuration 1 NO | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 110V | ||
Minimum Operating Temperature -40°C | ||
Operational Current Ie 6A | ||
Maximum Operating Temperature 70°C | ||
Depth 90mm | ||
Standards/Approvals EU 2011/65/EU, IEC 60068-2-30 and 60068-2-11, UTE C 63-100 specification II | ||
Width 54mm | ||
Length 94mm | ||
Pole and Throw Configuration 3P | ||
- Land van herkomst:
- BG
ABB UA26 Series Contactor, 6A Contact Current, 110/120V Coil Voltage - 1SBL241022R8410
This contactor is a 3‑pole control unit designed for capacitor switching in industrial electrical installations. It operates on an AC control circuit at 50/60 Hz and is intended for switching capacitor banks with high inrush characteristics while mounted on DIN‑rail systems.
Features & Benefits
• 6A operational current for handling capacitor circuits
• Accepts Peak inrush currents up to 100x nominal for short Peaks
• Built‑in 1NO auxiliary contact for control signalling
• Coil rated 110/120V for 50/60 Hz control compatibility
• Screw terminals enabling secure connections for field wiring
• Rated for continuous operation up to 70 °C ambient
• Accepts Peak inrush currents up to 100x nominal for short Peaks
• Built‑in 1NO auxiliary contact for control signalling
• Coil rated 110/120V for 50/60 Hz control compatibility
• Screw terminals enabling secure connections for field wiring
• Rated for continuous operation up to 70 °C ambient
Applications
• Suitable for switching capacitor banks in power factor correction systems
• Ideal for automation panels requiring DIN‑rail mounting
• Used for industrial reactive‑power management at medium voltages
• Can be used with control systems needing an auxiliary signalling contact
• Ideal for automation panels requiring DIN‑rail mounting
• Used for industrial reactive‑power management at medium voltages
• Can be used with control systems needing an auxiliary signalling contact
What protective devices are recommended for the auxiliary circuit?
Use gG fuses sized around 1.5 to 1.8A for the auxiliary circuit and 10A for gG protection to match the manufacturers short‑circuit protective device guidance.
How does the contactor perform across different ambient temperatures?
It is specified for operation in free Air from −40 °C up to +70 °C at rated control voltage, with reduced permissible capacitor power at higher temperatures.
What electrical endurance can be expected when used with discharged capacitors?
When capacitors are discharged to ≤50V before re‑energisation, electrical durability is specified as 100 000 operating cycles.
Which voltages and power levels can it handle for capacitor switching?
Permissible reactive power varies with system voltage and temperature — for example up to 30 kvar at 690V and 40 °C, with reduced kvar ratings at higher temperatures.
Gerelateerde Links
- ABB 1SBL24 Contactor 120 V Coil 4 A 110V 3 NO, 690V
- ABB 1SBL35 Contactor 120 V Coil 3 NO, 690V
- ABB 1SBL37 Contactor 120 V Coil 3 NO, 690V
- ABB 1SBL24 Contactor 3-Pole 3 NO, 690V
- ABB 1SBL24 Contactor 3-Pole 3 NO, 690V
- ABB 1SBL3 Contactor 3-Pole 120 V dc 690V
- ABB 1SBL41 Contactor 120 V dc Coil 1.3 kA 110V dc 3 NO, 690V
- ABB 1SBL2 Contactor 3-Pole 120 V dc 690V