Pico Technology ADC-24 & TERM Voltage Data Logger, USB 2.0, 8 Channel

Subtotaal (1 eenheid)*

€ 730,27

(excl. BTW)

€ 883,63

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 2 stuk(s) klaar voor verzending
  • 8 stuk(s) klaar voor verzending vanaf een andere locatie
  • Plus verzending 2 stuk(s) vanaf 20 november 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 730,27

*prijsindicatie

RS-stocknr.:
536-8834
Artikelnummer Distrelec:
304-11-393
Fabrikantnummer:
ADC-24 & TERM
Fabrikant:
Pico Technology
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Pico Technology

Product Type

Data Logger

Model Number

ADC-24 & TERM

Number of Channels

8

Measurement Parameters

Voltage

Interface Type

USB 2.0

Data Logger Type

Voltage

Power Source

USB

Minimum Operating Temperature

0°C

Maximum Operating Temperature

45°C

Height

36mm

Standards/Approvals

No

Hazardous Area Certification

No

Length

135mm

Width

184mm

Resolution

24 bit

Alarm

Yes

Maximum Measurement

2500 mV

Minimum Measurement

-2500 mV

Vrijgesteld

Land van herkomst:
GB

Pico Technology Data Logger, 8 Channels, 24 bit Resolution - ADC-24 & TERM


This data logger records voltage across multiple channels for monitoring and analysis in controlled environments. It operates from a USB power source and connects via a USB 2.0 Interface to offload recorded values. The instrument measures low-level signals within a symmetrical ±2500 mV span and is intended for use within a typical ambient range up to 45°C.

Features and Benefits:


• 8 channels enable simultaneous multi-point voltage capture
• 24 bit resolution delivers high-resolution measurement detail
• ±2500 mV range supports low-voltage signal monitoring
• USB power source simplifies field deployment and connection
• Built-in alarm notifies users when thresholds are exceeded

Applications


• Suitable for industrial low-voltage signal monitoring
• Ideal for multi-channel voltage trend logging in racks
• Used with PC interfaces for data acquisition and analysis
• Can be used for process validation within 0 to 45°C environments

What is the Interface used to transfer recorded data?


Data is transferred via a USB 2.0 interface.

Which temperature range is acceptable for continuous operation?


The device operates within an ambient range from 0°C to a maximum of 45°C.

How many channels can be recorded concurrently?


It records eight separate voltage channels at the same time.

What is the maximum measurement amplitude per channel?


Each channel measures up to 2500 mV and down to -2500 mV.

What type of measurement parameter does it acquire?


It acquires voltage signals with a 24 bit resolution.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.