Pico Technology PicoLog 1216 Voltage Data Logger, USB 2.0, 16 Channel

Subtotaal (1 eenheid)*

€ 277,07

(excl. BTW)

€ 335,25

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 11 stuk(s) klaar voor verzending
  • 22 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 277,07

*prijsindicatie

RS-stocknr.:
666-8163
Fabrikantnummer:
PICOLOG 1216 with terminal bd
Fabrikant:
Pico Technology
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Pico Technology

Product Type

Data Logger

Model Number

PicoLog 1216

Accuracy

±0.5 %

Measurement Parameters

Voltage

Number of Channels

16

Interface Type

USB 2.0

Data Logger Type

Voltage

Power Source

USB

Minimum Operating Temperature

0°C

Maximum Operating Temperature

70°C

Height

45mm

Standards/Approvals

RoHS Compliant

Hazardous Area Certification

No

Length

140mm

Width

100mm

Resolution

12 bit

Number of Readings per Channel

8000

Alarm

Yes

Land van herkomst:
GB

Pico Technology Data Logger, 16 Channels, Voltage Measurement Parameter - PICOLOG 1216 with Terminal bd


This data logger records electrical voltage across multiple inputs for industrial monitoring and analysis. It operates from a USB power source and connects via USB 2.0 for data transfer. Designed to function within typical ambient ranges, it monitors voltages while withstanding temperatures up to 70°C and down to 0°C. The device provides alarm capability for condition signalling and conforms to RoHS restrictions.

Features and Benefits:


• 16-channel input allows simultaneous multi-point voltage capture
• 12-bit resolution delivers precise quantisation for signals
• ±0.5% accuracy supports tight measurement tolerances
• 8000 readings per channel store extensive time-series data
• USB-powered operation removes need for external batteries

Applications


• Suitable for industrial voltage monitoring and diagnostics
• Ideal for laboratory test benches requiring multiple channels
• Used with USB 2.0 systems for straightforward data retrieval
• Can be used for process trending in moderate-temperature environments

How many samples can be stored on each channel?


Each channel can retain up to 8000 individual readings.

What Interface is provided for connection to a host computer?


A USB 2.0 Interface is used for both power and data transfer.

What environmental temperatures can the device tolerate during operation?


It operates between 0°C minimum and 70°C maximum.

What level of measurement granularity does the device offer?


Measurement resolution is 12-bit, providing discrete voltage quantisation.

Does the unit include any certification regarding hazardous-area use?


It has no hazardous-area certification and is not certified for such zones.