Recom REM3 DC/DC Converter, 12V dc/ 250 mA, 18V dc Input, 9V Input 3 W, Through Hole, 105 °C Max Temp -40 °C Min Temp,

Bulkkorting beschikbaar
Bekijk bulkkorting

Subtotaal (1 tube van 7 eenheden)*

€ 445,27

(excl. BTW)

€ 538,78

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 09 december 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.

Tube(s)
Per tube
Per stuk*
1 - 4€ 445,27€ 63,61
5 - 9€ 431,91€ 61,701
10 - 24€ 418,55€ 59,793
25 - 49€ 405,19€ 57,884
50 +€ 391,84€ 55,977

*prijsindicatie

RS-stocknr.:
162-2764
Fabrikantnummer:
REM3-1212S/A
Fabrikant:
Recom
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Recom

Product Type

DC/DC Converter

Output Voltage 1

12V dc

Minimum Input Voltage

9V

Maximum Input Voltage

18V dc

Output Current 1

250mA

Mount Type

Through Hole

MTBF

6444000h

Number of Outputs

1

Output Voltage Adjustment Range

±10 %

Number of Pins

24

Isolation Voltage

5kV ac

Package Type

DIP-24

Maximum Output Power

3W

Depth

10.4mm

Standards/Approvals

No

Series

REM3

Width

20.3mm

Length

31.8mm

Minimum Operating Temperature

-40°C

Efficiency

87%

Maximum Operating Temperature

105°C

Land van herkomst:
TW

Recom 3W DIP Single/Dual Output Regulated Isolated Medical DC-DC Converter - REM3 Series


The Recom REM3 is a series of medical grade, regulated DC/DC converters, featuring reinforced 5kVAC/1 minute isolation, low 2μA leakage and are 60601-1 3rd Ed. certified for 250VAC continuous working. The compact DIP24 package of these DC-DC converters offers tightly regulated single and dual outputs, even under no-load conditions. The outputs of the REM3 Series of converters are short circuit and overload protected. The DC-DC converters are fully certified to CB, IEC/EN and ANSI/AAMI standards and carry the CE and UL marks.

Reinforced Insulation for 250VAC Working Voltage

Clearance and Creepage Distance: 8mm

5kVAC I/P to O/P 2MOPP Isolation

2μA Patient Leakage Current

Industry Standard Pinout

2:1 and 4:1 Wide Input Range

Approvals

CB, IEC/EN, ANSI/AAMI, CE and UL

Standards

UL-60950-1, EN-55011, EN-55022, IEC/EN-60950-1, IEC/EN-60601-1

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres