Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy
- RS-stocknr.:
- 741-4320
- Fabrikantnummer:
- 1551A-9-DL
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.480,00
(excl. BTW)
€ 1.790,80
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- Verzending 1 stuk(s) vanaf 22 oktober 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.480,00 |
*prijsindicatie
- RS-stocknr.:
- 741-4320
- Fabrikantnummer:
- 1551A-9-DL
- Fabrikant:
- Fluke calibration
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Product Type | Digital Thermometer | |
| Maximum Temperature Measurement | 160°C | |
| Model Number | 1551A | |
| Probe Type | RTD | |
| Thermometer Type | Handheld | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Resolutions Supported | 0.001°C | |
| Battery Life | 300h | |
| Height | 25mm | |
| Standards/Approvals | EN 61326:2006 | |
| Hazardous Area Certification | ATEX | |
| Weight | 196g | |
| Length | 114mm | |
| Width | 57mm | |
| Temperature Scale | °C, Fahrenheit, F | |
| Minimum/Maximum Recordings | Yes | |
| Application | Industrial | |
| Intrinsically Safe | Yes | |
| Battery Type | 3 x AAA Alkaline | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Product Type Digital Thermometer | ||
Maximum Temperature Measurement 160°C | ||
Model Number 1551A | ||
Probe Type RTD | ||
Thermometer Type Handheld | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Resolutions Supported 0.001°C | ||
Battery Life 300h | ||
Height 25mm | ||
Standards/Approvals EN 61326:2006 | ||
Hazardous Area Certification ATEX | ||
Weight 196g | ||
Length 114mm | ||
Width 57mm | ||
Temperature Scale °C, Fahrenheit, F | ||
Minimum/Maximum Recordings Yes | ||
Application Industrial | ||
Intrinsically Safe Yes | ||
Battery Type 3 x AAA Alkaline | ||
Niet conform
- Land van herkomst:
- CN
Fluke Digital Thermometer, ±0.05°C Accuracy, 160°C Maximum Temperature Measurement - 1551A-9-DL
Features & Benefits
• Measures up to 160°C to cover common process ranges
• Intrinsically safe design allows use in classified hazardous areas
• Stores measurement data to assist traceable logging
• Wired RTD probe input enables robust sensor connectivity
**Applications**
• Ideal for temperature transmitter calibration in process control
• Used for custody transfer and PET calibration checks
• Can be used for on-site verification of industrial RTDs
• Used with loop and pressure calibrators during maintenance
What power source does it use and how long will it run between battery changes?
Which measurement scales and probe type are supported?
Is the instrument suitable for use in potentially explosive atmospheres?
How is measurement history handled for audits or verification?
Note
Supplied with
Gerelateerde Links
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL