Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy
- RS-stocknr.:
- 741-4320
- Fabrikantnummer:
- 1551A-9-DL
- Fabrikant:
- Fluke calibration
Momenteel niet beschikbaar
Sorry, we weten niet wanneer dit weer voorradig zal zijn.
- RS-stocknr.:
- 741-4320
- Fabrikantnummer:
- 1551A-9-DL
- Fabrikant:
- Fluke calibration
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Maximum Temperature Measurement | 160°C | |
| Product Type | Digital Thermometer | |
| Model Number | 1551A | |
| Thermometer Type | Handheld | |
| Probe Type | RTD | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Resolutions Supported | 0.001 | |
| Battery Life | 300h | |
| Width | 57mm | |
| Standards/Approvals | EN 61326:2006 | |
| Weight | 196g | |
| Length | 114mm | |
| Hazardous Area Certification | ATEX | |
| Height | 25mm | |
| Minimum/Maximum Recordings | Yes | |
| Application | Industrial | |
| Temperature Scale | °C, Fahrenheit, F | |
| Battery Type | 3 x AAA Alkaline | |
| Intrinsically Safe | Yes | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Maximum Temperature Measurement 160°C | ||
Product Type Digital Thermometer | ||
Model Number 1551A | ||
Thermometer Type Handheld | ||
Probe Type RTD | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Resolutions Supported 0.001 | ||
Battery Life 300h | ||
Width 57mm | ||
Standards/Approvals EN 61326:2006 | ||
Weight 196g | ||
Length 114mm | ||
Hazardous Area Certification ATEX | ||
Height 25mm | ||
Minimum/Maximum Recordings Yes | ||
Application Industrial | ||
Temperature Scale °C, Fahrenheit, F | ||
Battery Type 3 x AAA Alkaline | ||
Intrinsically Safe Yes | ||
Niet conform
- Land van herkomst:
- CN
Fluke Digital Thermometer, ±0.05°C Accuracy, 160°C Maximum Temperature Measurement - 1551A-9-DL
This digital thermometer is a battery-powered handheld instrument designed for temperature measurement and calibration in industrial settings where hazardous atmospheres may exist. It accepts an RTD probe input for single-point temperature monitoring and records minimum and maximum values, providing straightforward temperature checks and data capture for process maintenance tasks.
Features & Benefits
• ±0.05°C accuracy enhances precision for calibration work
• Measures up to 160°C to cover common process ranges
• Intrinsically safe design allows use in classified hazardous areas
• Stores measurement data to assist traceable logging
• Wired RTD probe input enables robust sensor connectivity
• Measures up to 160°C to cover common process ranges
• Intrinsically safe design allows use in classified hazardous areas
• Stores measurement data to assist traceable logging
• Wired RTD probe input enables robust sensor connectivity
**Applications**
• Suitable for daily thermometer checks in petrochemical plants
• Ideal for temperature transmitter calibration in process control
• Used for custody transfer and PET calibration checks
• Can be used for on-site verification of industrial RTDs
• Used with loop and pressure calibrators during maintenance
• Ideal for temperature transmitter calibration in process control
• Used for custody transfer and PET calibration checks
• Can be used for on-site verification of industrial RTDs
• Used with loop and pressure calibrators during maintenance
What power source does it use and how long will it run between battery changes?
It runs from three AAA alkaline cells and provides approximately 300 h of operation under typical use conditions.
Which measurement scales and probe type are supported?
Readings can be displayed in °C or Fahrenheit and the instrument accepts an RTD probe input for temperature sensing.
Is the instrument suitable for use in potentially explosive atmospheres?
Yes, it is certificated for intrinsic safety and carries ATEX-related classification for use in hazardous gas zones.
How is measurement history handled for audits or verification?
It features onboard data storage and records minimum and maximum values for retrospective review.
Note
Model number appended with a -9, -12, -20 indicates probe sheath length in inches. All probe diameters are 6.35 mm with the exception of the 1551A-9, which is 4.8 mm diameter
Supplied with
3 x AAA batteries and instruction manual on CD ROM
Gerelateerde Links
- Fluke calibration 1551A Handheld Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1551A Handheld Digital Thermometer 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1551A Handheld Digital Thermometer 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1551A Handheld Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1551A Handheld Digital Thermometer 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1551A Handheld Digital Thermometer 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1551A Recording Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1551A Recording Digital Thermometer 1 Input(s) ±0.05°C Accuracy, RSCAL