Fluke calibration 1552A Wired Digital Thermometer, PRT Probe, 1 Input(s), 300 °C Max, ±0.05°C Accuracy
- RS-stocknr.:
- 741-4330
- Fabrikantnummer:
- 1552A-12-DL
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 2.074,00
(excl. BTW)
€ 2.509,54
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Beperkte voorraad
- Plus verzending 2 stuk(s) vanaf 04 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 2.074,00 |
*prijsindicatie
- RS-stocknr.:
- 741-4330
- Fabrikantnummer:
- 1552A-12-DL
- Fabrikant:
- Fluke calibration
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Maximum Temperature Measurement | 300°C | |
| Product Type | Digital Thermometer | |
| Model Number | 1552A | |
| Thermometer Type | Wired | |
| Probe Type | PRT | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Battery Life | 300h | |
| Weight | 196g | |
| Hazardous Area Certification | ATEX | |
| Width | 57mm | |
| Standards/Approvals | EN 61326:2006 | |
| Length | 114mm | |
| Height | 25mm | |
| Minimum/Maximum Recordings | Yes | |
| Temperature Scale | °C, F, Fahrenheit | |
| Battery Type | AAA | |
| Intrinsically Safe | Yes | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Maximum Temperature Measurement 300°C | ||
Product Type Digital Thermometer | ||
Model Number 1552A | ||
Thermometer Type Wired | ||
Probe Type PRT | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Battery Life 300h | ||
Weight 196g | ||
Hazardous Area Certification ATEX | ||
Width 57mm | ||
Standards/Approvals EN 61326:2006 | ||
Length 114mm | ||
Height 25mm | ||
Minimum/Maximum Recordings Yes | ||
Temperature Scale °C, F, Fahrenheit | ||
Battery Type AAA | ||
Intrinsically Safe Yes | ||
Niet conform
Fluke Digital Thermometer, ±0.05°C Accuracy, 300h Battery Life - 1552A-12-DL
This digital thermometer provides a portable, battery‑powered reference for precise temperature measurement in industrial settings where explosive atmospheres may be present. It combines a fixed probe and readout in one handheld unit, designed for use across processing floors and outdoor sites to verify and calibrate process sensors.
Features & Benefits
• Accuracy of ±0.05°C ensuring repeatable measurements
• Intrinsically safe construction compliant with ATEX/IECEx
• Measures up to 300°C for high‑temperature process checks
• Internal logging option stores up to 10,000 time‑stamped readings
• Three AAA batteries deliver approximately 300 h operation
• Selectable resolution down to 0.001 for fine measurement detail
• Intrinsically safe construction compliant with ATEX/IECEx
• Measures up to 300°C for high‑temperature process checks
• Internal logging option stores up to 10,000 time‑stamped readings
• Three AAA batteries deliver approximately 300 h operation
• Selectable resolution down to 0.001 for fine measurement detail
**Applications**
• Suitable for calibrating process sensors in chemical plants
• Ideal for temperature checks during custody transfer procedures
• Used for verification of food‑processing sensor accuracy
• Can be used for maintenance of heating systems in facilities
• Suitable for on‑site instrument checks in hazardous zones
• Ideal for temperature checks during custody transfer procedures
• Used for verification of food‑processing sensor accuracy
• Can be used for maintenance of heating systems in facilities
• Suitable for on‑site instrument checks in hazardous zones
What sensor type does it use and how does that affect stability?
It uses a PRT thin‑film element with low hysteresis, which reduces drift and maintains measurement repeatability over time.
How is data retrieved and what are the logging interval options?
Logged readings are stored internally and can be recorded at intervals from 2s up to 60min, with RS‑232 access to calibration parameters if required.
What operating ambient temperatures will not degrade the readout accuracy?
The readout remains within specification when operated in ambient conditions from −10°C to 50°C.
How does the display assist Rapid field measurements?
The LCD rotates 90° for viewing at different angles and includes a user‑settable trend/stability indicator to confirm when a source has stabilised.
Note
Model number appended with a -9, -12, -20 indicates probe sheath length in inches. All probe diameters are 6.35 mm with the exception of the 1551A-9, which is 4.8 mm diameter
Supplied with
3 x AAA batteries and instruction manual on CD ROM
Gerelateerde Links
- Fluke calibration 1552A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - RSCAL
- Fluke calibration 1552A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - UKAS
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - RSCAL
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - UKAS
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - RSCAL
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - UKAS
