Belden, 500 m Cat6 Cat6 Cable, Grey Unterminated to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- RS-stocknr.:
- 631-577
- Fabrikantnummer:
- 7965ENH.01500
- Fabrikant:
- Belden
Subtotaal (1 rol van 500 meter)*
€ 650,87
(excl. BTW)
€ 787,55
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- 1 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 650,87 | € 1,302 |
*prijsindicatie
- RS-stocknr.:
- 631-577
- Fabrikantnummer:
- 7965ENH.01500
- Fabrikant:
- Belden
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Belden | |
| Product Type | Cat6 Cable | |
| Cable Length | 500m | |
| LAN Category | Cat6 | |
| Shield Type | U/UTP | |
| Connector Type A | Unterminated | |
| Connector Type B | Unterminated | |
| Jacket Material | Low Smoke Zero Halogen | |
| Jacket Colour | Grey | |
| Standards/Approvals | CE, EU, ISO/IEC 11801-1, IEC 62821 | |
| Voltage | 72V | |
| Series | 7965ENH | |
| Alles selecteren | ||
|---|---|---|
Merk Belden | ||
Product Type Cat6 Cable | ||
Cable Length 500m | ||
LAN Category Cat6 | ||
Shield Type U/UTP | ||
Connector Type A Unterminated | ||
Connector Type B Unterminated | ||
Jacket Material Low Smoke Zero Halogen | ||
Jacket Colour Grey | ||
Standards/Approvals CE, EU, ISO/IEC 11801-1, IEC 62821 | ||
Voltage 72V | ||
Series 7965ENH | ||
- Land van herkomst:
- HU
Belden Power Cable Assembly, 500m Cable Length, Grey Jacket - 7965ENH.01500
This power cable assembly provides a long-run electrical distribution solution for installations requiring extended reach and consistent performance. Supplied as an un-terminated length, it is intended for integration into systems where custom termination or on-site connections are required. The grey jacket comprises a low smoke zero halogen compound suitable for internal environments and areas where reduced toxic emissions are needed during combustion.
Features & Benefits
• 72V rating supports low-voltage power distribution needs
• U/UTP construction reduces electromagnetic coupling for installations
• 500m length enables long-distance runs without splicing
• LSZH grey outer sheath minimises hazardous emissions if ignited
• CE and ISO/IEC 11801-1 alignment ensures system-level interoperability
• U/UTP construction reduces electromagnetic coupling for installations
• 500m length enables long-distance runs without splicing
• LSZH grey outer sheath minimises hazardous emissions if ignited
• CE and ISO/IEC 11801-1 alignment ensures system-level interoperability
**Applications**
• Suitable for power distribution in building automation networks
• Ideal for connecting equipment in commercial electrical installations
• Used for routing power in control cabinets and machine rooms
• Can be used for installations requiring standards-compliant cabling
• Ideal for connecting equipment in commercial electrical installations
• Used for routing power in control cabinets and machine rooms
• Can be used for installations requiring standards-compliant cabling
What conductor shielding approach does it use and why does that matter?
It employs U/UTP shielding, meaning the cable has an overall unshielded pair configuration with an unshielded overall braid absent
this arrangement lowers pair-to-pair interference while keeping flexibility and ease of termination for typical data-adjacent power runs.
How does the jacket material affect onsite safety procedures?
The low smoke zero halogen sheath produces reduced corrosive gases and smoke density during combustion, which can simplify evacuation and ventilation planning and limit damage to nearby electronic equipment.
Is the cable suitable for environments with regulatory testing to IEC 62821?
The assembly meets IEC 62821 ratings, indicating it has been evaluated against the standards criteria and is appropriate where that specification is required.
How should installers handle the unterminated ends for reliable connections?
Ends must be prepared and terminated in accordance with site wiring practices using suitable lugs or connectors, ensuring correct conductor exposure and secure mechanical clamping to maintain the 72V performance.
Gerelateerde Links
- Belden Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden 7965ENH Cat6 Ethernet Cable Blue, Unshielded Unscreened Low Smoke Zero Halogen Sheath
- Belden 7965ENH Cat6 Ethernet Cable Blue, Unshielded Unscreened Low Smoke Zero Halogen Sheath
- Belden Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, F/UTP
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, F/UTP
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, SF/UTP