Belden, 305 m Cat6 Cat6 Cable, Grey Unterminated to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- RS-stocknr.:
- 631-651
- Fabrikantnummer:
- 7965ENH.01305
- Fabrikant:
- Belden
Subtotaal (1 rol van 305 meter)*
€ 397,04
(excl. BTW)
€ 480,42
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- 1 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 397,04 | € 1,302 |
*prijsindicatie
- RS-stocknr.:
- 631-651
- Fabrikantnummer:
- 7965ENH.01305
- Fabrikant:
- Belden
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Belden | |
| Product Type | Cat6 Cable | |
| Cable Length | 305m | |
| LAN Category | Cat6 | |
| Shield Type | U/UTP | |
| Connector Type A | Unterminated | |
| Connector Type B | Unterminated | |
| Jacket Material | Low Smoke Zero Halogen | |
| Jacket Colour | Grey | |
| Standards/Approvals | ISO/IEC 11801-1, IEC 62821, CE, EU | |
| Voltage | 72V | |
| Series | 7965ENH | |
| Alles selecteren | ||
|---|---|---|
Merk Belden | ||
Product Type Cat6 Cable | ||
Cable Length 305m | ||
LAN Category Cat6 | ||
Shield Type U/UTP | ||
Connector Type A Unterminated | ||
Connector Type B Unterminated | ||
Jacket Material Low Smoke Zero Halogen | ||
Jacket Colour Grey | ||
Standards/Approvals ISO/IEC 11801-1, IEC 62821, CE, EU | ||
Voltage 72V | ||
Series 7965ENH | ||
- Land van herkomst:
- HU
Belden Power Cable Assembly, 305m Cable Length, Grey Jacket - 7965ENH.01305
This power cable assembly delivers insulated electrical distribution for industrial and commercial installations, providing a shielded Multicore conductor in a low-emission jacket for use where reduced smoke and toxic gas output are required. It is intended for up to 72V systems and deployed in environments that demand compliance with international wiring standards and EU conformity.
Features & Benefits
• U/UTP shielding reduces electromagnetic interference and crosstalk
• Low Smoke Zero Halogen jacket limits harmful emissions in fires
• Rated for 72V systems to support low-voltage power distribution
• CE and EU approved for regulatory acceptance across installations
• Meets ISO/IEC 11801-1 and IEC 62821 standards for structured cabling
• Low Smoke Zero Halogen jacket limits harmful emissions in fires
• Rated for 72V systems to support low-voltage power distribution
• CE and EU approved for regulatory acceptance across installations
• Meets ISO/IEC 11801-1 and IEC 62821 standards for structured cabling
**Applications**
• Suitable for factory automation low-voltage power runs
• Ideal for electrical control panel internal wiring
• Used for power distribution in electronic test rigs
• Can be used for mechanical systems requiring reduced-emission cabling
• Ideal for electrical control panel internal wiring
• Used for power distribution in electronic test rigs
• Can be used for mechanical systems requiring reduced-emission cabling
What handling considerations apply for long reels during installation?
Reels of this cable require appropriate cable-pulling techniques and supports to prevent excessive bend radii and tensile stress
secure drum rotation and avoid kinking to maintain conductor integrity.
How does the jacket material influence fire-site conditions?
The low-emission compound produces significantly lower smoke density and reduced corrosive gases compared with conventional PVC, improving visibility and limiting equipment damage during incidents.
What connector preparation is required on-site?
The cable is supplied without terminations, so installers must strip the jacket and prepare individual cores for crimping, soldering or screw termination according to system requirements and safety practices.
Are there screening considerations when routing parallel signal cables?
The unshielded pairs within the screened assembly benefit from the overall U/UTP construction, so maintain separation from high-current conductors and route with the screen earthed at a single point to control noise.
Gerelateerde Links
- Belden Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden 7965ENH Cat6 Ethernet Cable Blue, Unshielded Unscreened Low Smoke Zero Halogen Sheath
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, SF/UTP
- Belden Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, U/UTP
- Belden 7965ENH Cat6 Ethernet Cable Blue, Unshielded Unscreened Low Smoke Zero Halogen Sheath
