Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid, 0.2L/min Min, 150L/min Max

Afbeelding representeert productcategorie

Subtotaal (1 eenheid)*

€ 611,05

(excl. BTW)

€ 739,37

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 7 stuk(s) vanaf 14 september 2026
  • Plus verzending 3 stuk(s) vanaf 14 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 611,05

*prijsindicatie

RS-stocknr.:
256-6155
Artikelnummer Distrelec:
303-51-194
Fabrikantnummer:
DMA25-AAABA1
Fabrikant:
Endress+Hauser
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Endress+Hauser

Product Type

Flow Meter

Media Monitored

Liquid

Device Type

Electromagnetic Flowmeter

Minimum Flow Rate

0.2L/min

Maximum Flow Rate

150L/min

Housing Material

316L Stainless Steel

Connection Type

Thread

Maximum Pressure

16bar

Minimum Media Temperature

-10°C

IP Rating

IP65, IP67

Maximum Supply Voltage

30V dc

Maximum Media Temperature

70°C

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

60°C

Standards/Approvals

CE mark

Series

DMA25

Land van herkomst:
FR

Endress+Hauser DMA25 Series Flow Meter, 0.2 L/min Minimum Flow Rate, 150 L/min Maximum Flow Rate - DMA25-AAABA1


This flow metre measures volumetric liquid flow using electromagnetic sensing and is suited to inline monitoring within industrial systems. It is designed for threaded-connection installations and performs across typical process temperature ranges while operating from a low-voltage DC supply. The unit is enclosed in a robust 316L stainless-steel housing and accommodates moderate process pressures for general plant integration.

Features and Benefits:


• 0.2-150 L/min span delivering wide operational coverage for varied rates
• 30V DC maximum supply enabling low-voltage control-system integration
• IP65/IP67 enclosure allowing wet-area and wash-down operation
• 16 bar pressure rating supporting pressurised process loops
• -10 to 70 °C media capability handling cold and warm liquids
• Threaded connection type permitting simple inline replacement

Applications


• Suitable for metering chemical-dosing lines in processing plants
• Ideal for water distribution and recirculation loops
• Used with OEM skid-mounted equipment requiring compact sensors
• Can be used for HVAC chilled-water flow monitoring
• Suitable for food-processing rinse circuits compatible with stainless wetted parts

What materials contact the fluid and how does that affect compatibility?


The wetted parts are made from 316L stainless steel, which offers good corrosion resistance for many aqueous and mildly aggressive liquids.

How does the device manage exposure to wash-down conditions?


The enclosure meets IP65 and IP67 levels, providing protection against dust ingress and temporary immersion, enabling use in areas subject to cleaning procedures.

What electrical constraints should be observed during installation?


The transmitter must be supplied at no more than 30V DC and connected following the plant’s low-voltage wiring standards to ensure proper operation.

What flow and pressure limits define safe operation?


The unit measures flows from 0.2 L/min up to 150 L/min and is rated for process pressures up to 16 bar to match common industrial circuits.

What temperature boundaries apply to the device and the media?


The allowable ambient operating temperature extends down to -10 °C and the media temperature range reaches up to 70 °C for standard applications.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres