Fluke 1535 Insulation Resistance Tester, 250 V Min, 2500 V Max, 500 GΩ CAT IV
- RS-stocknr.:
- 283-7401
- Artikelnummer Distrelec:
- 304-20-196
- Fabrikantnummer:
- FLUKE-1535
- Fabrikant:
- Fluke
Afbeelding representeert productcategorie
Subtotaal (1 eenheid)*
€ 1.628,00
(excl. BTW)
€ 1.969,88
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.628,00 |
*prijsindicatie
Kalibratie-opties
- Calibration Type:
- RSCAL
- RS-stocknr.
- 283-7403
Per stuk
€ 1.697,00
(excl. BTW)
€ 2.053,37
(incl. BTW)
- RS-stocknr.:
- 283-7401
- Artikelnummer Distrelec:
- 304-20-196
- Fabrikantnummer:
- FLUKE-1535
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Model Number | 1535 | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Resistance Tester | |
| Maximum Test Voltage | 2500V | |
| Minimum Test Voltage | 250V | |
| Display Type | LCD | |
| Test Current | 5mA | |
| Power Source | Battery | |
| Battery Type | AA Alkaline | |
| Insulation Testing Resistance | 500GΩ | |
| Minimum Operating Temperature | -10°C | |
| Safety Category Voltage | 600V | |
| Safety Category Level | CAT IV | |
| Maximum Operating Temperature | 50°C | |
| Width | 211mm | |
| Standards/Approvals | Pollution Degree 2 IEC 615571, IEC 610101 | |
| Length | 93mm | |
| Height | 184mm | |
| Weight | 1.3kg | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Model Number 1535 | ||
Product Type Insulation Tester | ||
Tester Type Insulation Resistance Tester | ||
Maximum Test Voltage 2500V | ||
Minimum Test Voltage 250V | ||
Display Type LCD | ||
Test Current 5mA | ||
Power Source Battery | ||
Battery Type AA Alkaline | ||
Insulation Testing Resistance 500GΩ | ||
Minimum Operating Temperature -10°C | ||
Safety Category Voltage 600V | ||
Safety Category Level CAT IV | ||
Maximum Operating Temperature 50°C | ||
Width 211mm | ||
Standards/Approvals Pollution Degree 2 IEC 615571, IEC 610101 | ||
Length 93mm | ||
Height 184mm | ||
Weight 1.3kg | ||
- Land van herkomst:
- CN
Fluke Insulation Tester, 500GΩ Insulation Testing Resistance, 2500V Maximum Test Voltage - FLUKE-1535
This insulation tester is a portable handheld diagnostic instrument designed for field and workshop insulation resistance assessment across industrial and renewable-energy settings. It delivers selectable test voltages from 250V to 2500V and measures very high resistance values to assist technicians in verifying insulation integrity and locating degradation on electrical assets.
Features & Benefits
• Selectable voltages 250–2500V for tailored testing ranges
• Insulation measurement capability up to 500GΩ for high‑resistance detection
• Short‑circuit current up to 5mA for faster, stable readings
• CAT IV 600V safety rating for use near incoming supply points
• AA battery operation enabling long field use without mains power
• LCD display for clear visualisation of measured values
• Insulation measurement capability up to 500GΩ for high‑resistance detection
• Short‑circuit current up to 5mA for faster, stable readings
• CAT IV 600V safety rating for use near incoming supply points
• AA battery operation enabling long field use without mains power
• LCD display for clear visualisation of measured values
**Applications**
• Suitable for insulation testing of motors and generators on site
• Ideal for commissioning and maintenance of solar installations
• Used for preventive maintenance in industrial electrical systems
• Can be used for troubleshooting insulation faults on factory equipment
• Ideal for commissioning and maintenance of solar installations
• Used for preventive maintenance in industrial electrical systems
• Can be used for troubleshooting insulation faults on factory equipment
How many measurements can I expect between battery changes?
Using AA alkaline cells, the unit can perform over 1,300 tests at the highest test voltage on a single set of batteries.
Are there functions to assist insulation condition analysis?
Yes. It calculates Polarisation Index and Dielectric Absorption Ratio automatically to reduce environmental influence on results.
What additional measurements does the Advanced variant offer?
The Advanced instrument provides AC/DC voltage and resistance measurements Plus adjustable test voltage in 100V steps and ramp test mode.
How does the instrument manage charged capacitive circuits?
Charging and discharging behaviour is specified
typical charge rate for capacitive loads is 5s/μF and discharge rate is 1.5s/μF.
Gerelateerde Links
- Fluke 1535 Insulation Tester 2500 V Max, 500 GΩ CAT IV
- Fluke 1537 Insulation Tester 2500 V Max, 500 GΩ CAT IV
- Fluke 1507 Insulation Tester 1000 V Max CAT IV
- Fluke 1577 Insulation Tester 1000 V Max CAT IV
- Fluke 1587 FC Insulation Tester 1000 V Max CAT III
- Megger MIT2500 Insulation Tester 2500 V Max, 200 GΩ CAT IV
- Fluke 1555 Insulation Tester 10000 V Max CAT IV, CAT III
- Fluke 1550C Insulation Tester 5000 V Max CAT IV, CAT III