Eaton xEffect MCB, 2P, 16A Curve C, 240 → 415V AC, 10 kA Breaking Capacity
- RS-stocknr.:
- 847-3285
- Fabrikantnummer:
- 102170 FAZ-C16/2-NA
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 74,76
(excl. BTW)
€ 90,46
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- Plus verzending 10 stuk(s) vanaf 29 december 2025
- Plus verzending 10 stuk(s) vanaf 13 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 74,76 |
*prijsindicatie
- RS-stocknr.:
- 847-3285
- Fabrikantnummer:
- 102170 FAZ-C16/2-NA
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Number of Poles | 2 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240 → 415V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Length | 35.4mm | |
| Width | 105mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 76mm | |
| Model Number | FAZ-C16/2-NA | |
| Terminal Contact Type | Clip-on, Screw | |
| Reset Actuator Type | Toggle Switch | |
| Application | Commercial, Residential | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Number of Poles 2 | ||
Current Rating 16A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240 → 415V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Length 35.4mm | ||
Width 105mm | ||
Mounting Style DIN Rail Mount | ||
Depth 76mm | ||
Model Number FAZ-C16/2-NA | ||
Terminal Contact Type Clip-on, Screw | ||
Reset Actuator Type Toggle Switch | ||
Application Commercial, Residential | ||
Eaton MCB, 76mm Depth, Type C Tripping - FAZ Series - 102170 FAZ-C16/2-NA
Safeguard your electrical circuits with this MCB from Eaton. It does the job by automatically switching off electric systems during abnormal conditions. With a 10kA breaking capacity, the circuit breaker can handle high current loads without any damage, providing protection for your operations. A wide voltage range of 240 to 415V means it's a versatile option for residential and industrial applications. As a result, you'll find this high achiever widely used with relays, power supplies and motor control circuits.
Features & Benefits
• DIN rail mounting for easy installation
• Compact dimensions of 105 (W) x 76 (D) x 35.4mm (L) make it suitable for setups with limited space
• Compact dimensions of 105 (W) x 76 (D) x 35.4mm (L) make it suitable for setups with limited space
How do I know the contact position on this MCB?
This MCB has green and red indicators so you can easily identify its ON and OFF positions at a glance.
What does type-C tripping mean?
A type-C MCB like this one will work through a high spike of current, up to five to ten times its rated current, before it trips. This minimises nuisance trips and makes it suitable for both heavy commercial loads and light fixtures.
Note
Eaton formerly known as Moeller
Gerelateerde Links
- Eaton xEffect MCB 16A Curve C 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve B 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve D 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 96V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 96V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 60V DC, 10 kA Breaking Capacity