Siemens, SENTRON MCCB 4P 200A, Breaking Capacity 35 kA, Fixed Mount
- RS-stocknr.:
- 257-194
- Fabrikantnummer:
- 3VA5320-5GC41-2AA0
- Fabrikant:
- Siemens
Subtotaal (1 eenheid)*
€ 2.360,00
(excl. BTW)
€ 2.855,60
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 02 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 2.360,00 |
*prijsindicatie
- RS-stocknr.:
- 257-194
- Fabrikantnummer:
- 3VA5320-5GC41-2AA0
- Fabrikant:
- Siemens
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Siemens | |
| Range | SENTRON | |
| Series | 3VA5 | |
| Number of Poles | 4 | |
| Current Rating | 200A | |
| Breaking Capacity at Maximum Voltage Rating | 35 kA | |
| Mounting Style | Fixed | |
| Alles selecteren | ||
|---|---|---|
Merk Siemens | ||
Range SENTRON | ||
Series 3VA5 | ||
Number of Poles 4 | ||
Current Rating 200A | ||
Breaking Capacity at Maximum Voltage Rating 35 kA | ||
Mounting Style Fixed | ||
- Land van herkomst:
- CZ
The Siemens Molded Case Circuit Breaker is designed to enhance system protection in various applications. Engineered with a breaking capacity class M it provides reliable line protection with a notable performance rating of 35 kA at 480 V. The innovative design incorporates a TM230 overload protection mechanism ensuring effective management of both short circuit and overload conditions. With a robust mechanical service life of 20000 operating cycles this circuit breaker caters to rigorous operational demands while maintaining a compact and user friendly structure.
Equipped with adjustable response settings providing tailored protection
Designed for high short circuit current breaking capacity to ensure safety
Offers a substantial operational temperature range making it reliable in extreme conditions
No requirement for additional components streamlining the installation process
Incorporates features that prevent accidental overload enhancing system longevity
Designed for high short circuit current breaking capacity to ensure safety
Offers a substantial operational temperature range making it reliable in extreme conditions
No requirement for additional components streamlining the installation process
Incorporates features that prevent accidental overload enhancing system longevity
Gerelateerde Links
- Siemens Breaking Capacity 35 kA, Fixed Mount
- Siemens Breaking Capacity 7 kA, Fixed Mount
- Siemens Breaking Capacity 65 kA, Fixed Mount
- Siemens Breaking Capacity 100 kA, Fixed Mount
- Siemens Breaking Capacity 35 kA, Fixed Mount
- Siemens Breaking Capacity 35 kA, Fixed Mount
- Siemens Breaking Capacity 35 kA, Fixed Mount
- Siemens Breaking Capacity 35 kA, Fixed Mount