ABB, SACE Tmax XT, XT2N Molded Case Circuit Breaker 3-Pole 100A, Breaking Capacity 10 kA, Fixed

Subtotaal (1 eenheid)*

€ 506,52

(excl. BTW)

€ 612,89

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 2 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 506,52

*prijsindicatie

RS-stocknr.:
232-0236
Fabrikantnummer:
1SDA067018R1 XT2N 160 TMA 100A FF
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Range

SACE Tmax XT

Product Type

Molded Case Circuit Breaker

Series

XT2N

Number of Poles

3

Current Rating

100A

Breaking Capacity

10kA

Mount Type

Fixed

Rated AC Voltage

690V ac

Rated DC Voltage

500V dc

Terminal Type

Bolt

Depth

82.5mm

Standards/Approvals

IEC

Width

90mm

Height

130mm

Break Time

Instantaneous

Land van herkomst:
IT

ABB XT2N Series Molded Case Circuit Breaker, 100A Current Rating, 690V AC Rated AC Voltage - 1SDA067018R1 XT2N 160 TMA 100A FF


This moulded case circuit-breaker provides overcurrent protection for three-phase electrical systems in industrial environments. It is designed for fixed installation with bolt-style connections and delivers Rapid interruption of fault currents using an instantaneous trip element suited to applications requiring prompt disconnection. The device is compatible with both AC and DC supply arrangements and is built to meet international IEC standards.

Features and Benefits:


• 100 A rating delivers consistent conductor protection and load control
• 3‑pole configuration ensures simultaneous phase interruption for safety
• 10 kA breaking capacity limits prospective fault energy exposure
• Instantaneous trip offers immediate response to severe short circuits
• Rated for 690V AC operation for high-voltage distribution uses
• Bolt terminals provide secure, low-resistance connections

Applications


• Suitable for protection of industrial motor feeders and drives
• Ideal for switchboard sections in manufacturing facilities
• Used with DC control circuits up to 500V for battery-based systems
• Can be used for distribution protection in automation panels

What mounting method does it require for installation?


It is intended for fixed mounting, requiring a secure panel or chassis location and appropriate mechanical fastening to support the breaker body during operation.

Which Terminal style should installers expect to handle?


The device uses bolt-type terminals that necessitate torque-controlled fastening for reliable electrical contact and to prevent loosening under vibration.

How does the unit behave under DC supply compared with AC?


It is rated to interrupt DC currents up to the specified voltage, providing separation capability for DC circuits at the declared maximum, though DC arcing characteristics differ from AC and require correct application.

What standards govern its Basic design and testing?


The construction and performance adhere to IEC requirements, ensuring standardised test criteria for current interruption and endurance.

Gerelateerde Links