ABB, Tmax XT, 1SDA06 Molded Case Circuit Breaker 4-Pole 125A, Breaking Capacity 4 kA, Fixed

Subtotaal (1 eenheid)*

€ 552,02

(excl. BTW)

€ 667,94

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 5 stuk(s) vanaf 29 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 552,02

*prijsindicatie

RS-stocknr.:
236-7280
Fabrikantnummer:
1SDA067409R1 XT1C 160 TMD 125A FF
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Product Type

Molded Case Circuit Breaker

Range

Tmax XT

Series

1SDA06

Number of Poles

4

Current Rating

125A

Breaking Capacity

4kA

Rated AC Voltage

690V ac

Mount Type

Fixed

Rated DC Voltage

500V dc

Terminal Type

Screw

Depth

70mm

Width

101.6mm

Standards/Approvals

IEC

Height

130mm

Tripping Mechanism

Thermomagnetic

Break Time

Instantaneous

Land van herkomst:
IT

ABB 1SDA06 Series Molded Case Circuit Breaker, 125A Current Rating, 690V AC Rated AC Voltage - 1SDA067409R1 XT1C 160 TMD 125A FF


This moulded case circuit breaker provides overload and short-circuit protection for industrial electrical systems. Designed for fixed installation, it offers four-pole protection and operates with a thermomagnetic trip mechanism suited to mixed fault profiles. It is suitable for use in three-phase and DC distribution arrangements where compact, panel-mounted protection is required.

Features and Benefits:


• 125A rating delivers steady continuous current handling • Thermomagnetic tripping offers combined thermal and magnetic protection • 4kA breaking capacity limits fault energy during short circuits • Rated to 690V AC and 500V DC supports AC and DC networks • Screw terminals ensure secure conductor connections

Applications


• Suitable for motor control panels requiring overcurrent protection • Ideal for distribution boards in industrial automation systems • Used for protection of DC-powered control circuits and battery systems • Can be used in electrical switchgear for manufacturing plants

How is it mounted within an electrical enclosure?


It installs as a fixed-mount device designed for secure panel attachment and stable connection in Compact enclosures.

What Terminal connection method does it use for conductors?


It employs screw-type terminals that provide mechanical retention and electrical contact for a range of cable sizes.

Which standards govern its Basic performance?


It complies with IEC specifications for circuit-breaking performance and safety characteristics.

How does the trip mechanism respond to different fault types?


The thermomagnetic arrangement provides time-delayed response to overloads via the thermal element and instantaneous interruption of high-magnitude faults via the magnetic element.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.