1SDA067426R1 XT1N 160 TMD 160A 3P+N FF
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Range

Tmax XT

Product Type

Molded Case Circuit Breaker

Series

1SDA06

Number of Poles

4

Current Rating

160A

Breaking Capacity

5kA

Mount Type

Fixed

Rated AC Voltage

690V ac

Rated DC Voltage

500V dc

Terminal Type

Screw

Width

101.6mm

Standards/Approvals

IEC

Depth

70mm

Height

130mm

Tripping Mechanism

Thermomagnetic

Break Time

Instantaneous

Land van herkomst:
IT

ABB 1SDA06 Series Molded Case Circuit Breaker, 160A Current Rating, 690V AC Rated AC Voltage - 1SDA067426R1 XT1N 160 TMD 160A 3P+N FF


This moulded-case circuit breaker provides overcurrent protection and switching for three-phase systems with an additional NEUTRAL pole in industrial installations. It operates using a combined thermal and magnetic tripping arrangement to interrupt faults rapidly, and is designed for fixed mounting in control panels and distribution assemblies.

Features and Benefits:


• Thermomagnetic trip offers thermal overload and magnetic short-circuit protection • Rated for continuous 160 A operation for steady current handling • Interrupting capability of 5 kA for moderate fault clearing • Suitable for use up to 690V AC in high-voltage distribution • Compatible with 500V DC systems for DC switching requirements • Screw terminals enable secure conductor connection in installations

Applications


• Suitable for motor control and protection in automation panels • Ideal for distribution board protection in manufacturing facilities • Used with DC supply sections requiring up to 500V isolation • Can be used for service-entrance switching in industrial sites • Used for multi-pole protection where NEUTRAL isolation is required

What mounting arrangement is required for installation?


It is intended for fixed mounting, so it must be secured to a panel or enclosure using appropriate hardware and clearances for ventilation.

How many poles does it provide and what is their configuration?


The device contains four poles, providing three-phase conductors Plus a dedicated NEUTRAL pole for selective isolation.

Which Terminal type is provided for conductor connection?


Connections are MADE via screw-type terminals designed for reliable clamping of supply and load conductors.

What standards of construction does it follow?


The design conforms to established IEC standards for circuit-breaker construction and performance.

What physical form factor affects panel layout?


The breaker has a Compact fixed-body format with a shallow depth to aid installation in confined panel spaces.

Gerelateerde Links