ABB, Tmax XT, Tmax XT Molded Case Circuit Breaker 3-Pole 52A, Breaking Capacity 65 kA, Fixed

Subtotaal (1 eenheid)*

€ 386,33

(excl. BTW)

€ 467,46

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 1 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 386,33

*prijsindicatie

RS-stocknr.:
237-6225
Fabrikantnummer:
1SDA067051R1 XT2N 160 MA 52 FF
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Range

Tmax XT

Product Type

Molded Case Circuit Breaker

Series

Tmax XT

Number of Poles

3

Current Rating

52A

Breaking Capacity

65kA

Mount Type

Fixed

Rated AC Voltage

690V ac

Rated DC Voltage

500V dc

Terminal Type

Fixed

Standards/Approvals

IEC, RoHS, CE

Width

90mm

Height

130mm

Depth

82.5mm

Reset Actuator Type

Lever

Tripping Mechanism

Magnetic

Land van herkomst:
IT

ABB Tmax XT Series Molded Case Circuit Breaker, 52A Current Rating, 65kA Breaking Capacity - 1SDA067051R1 XT2N 160 MA 52 FF


This moulded case circuit breaker provides overcurrent protection for three-phase industrial installations, functioning as a fixed-terminal protective device with a manual reset lever. It is intended for use in electrical distribution and motor protection where Compact fixed mounting and magnetic tripping are required.

Features and Benefits:


• 65kA breaking capacity delivers high fault interruption performance • 52A rating enables defined protection for medium-current circuits • Magnetic trip operation offers Rapid short-circuit response • Fixed Terminal arrangement simplifies secure panel installation • Rated for 690V AC and 500V DC supports mixed-supply environments • Conforms to IEC, RoHS and CE standards for regulatory alignment

Applications


• Suitable for protecting industrial motor circuits requiring fast fault isolation • Ideal for distribution panels in manufacturing and automation centres • Used with DC and AC supplies in mixed-voltage installations • Can be used for switchgear retrofits needing a Compact fixed MCCB

How is the device reset after a trip?


A manual lever actuator is provided to return the breaker to service following a trip event.

What pole configuration does the unit use?


It uses a three-pole arrangement to interrupt all phases simultaneously for balanced system protection.

What mounting approach is required for installation?


The breaker is designed for fixed mounting and requires secure attachment to a panel or enclosure.

Which Terminal type is fitted and how does that affect connections?


Fixed terminals are used, requiring appropriate cable lugs and secure bolted connections during wiring.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.