Schneider Electric LUC DOL Starter, DOL, 690V ac, 3 kW, 3 Phase, IP20, IP40

Subtotaal (1 eenheid)*

€ 74,59

(excl. BTW)

€ 90,25

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 12 stuk(s) vanaf 07 september 2026
  • Plus verzending 22 stuk(s) vanaf 07 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 74,59

*prijsindicatie

RS-stocknr.:
272-454
Artikelnummer Distrelec:
136-22-697
Fabrikantnummer:
LUCA05FU
Fabrikant:
Schneider Electric
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Schneider Electric

Product Type

DOL Starter

Power Rating

3kW

Sub Type

DOL

Number of Phases

3

Current Rating

5A

IP Rating

IP20, IP40

Number of Poles

3

Overall Length

66mm

Maximum Voltage

690V ac

Standards/Approvals

CSA C22.2 No. 14 type E, UL 508 Type E, IEC 60947-6-2, EN 60947-6-2

Hazardous Area Certification

ATEX

Overall Width

45mm

Overall Depth

60mm

Series

LUC

Vrijgesteld

Schneider Electric LUC Series DOL Starter, 5A Current, 3kW Power - LUCA05FU


This DOL starter is a Compact direct-on-line control unit designed to start and protect 3-phase motors in industrial installations. It integrates thermal-magnetic overload and short-circuit protection with phase loss and imbalance monitoring, and is intended for plug-in use on compatible power bases in automation and electrical control panels.

Features & Benefits


• 1.25 to 5A adjustable current protects motor windings
• 3kW at 690V AC delivers high-voltage motor starting capacity
• Class10 thermal release offers time-delayed overload response
• 110 to 240V AC or 110 to 220V DC Coil for flexible control supply
• ATEX certified for use in hazardous-area installations
• IP20 front and IP40 front-outside protection for panel mounting

Applications


• Suitable for starting 3-phase motors up to 3kW at 690V AC
• Ideal for control panels requiring hazardous-area compliant starters
• used with plug-in power bases such as LUB12 and LUB32
• Can be used for reversing contactor to breaker assemblies in motor control
• Suitable for machinery where phase-failure protection is required

What control supply voltages will operate the unit?


It accepts 110 to 240V AC and 110 to 220V DC with operation limits of 88 to 264V AC and 88 to 242V DC.

How quickly does it operate during switching events?


Typical operating times are 50 MS to close and 35 MS to open on compatible bases.

What environmental conditions can it tolerate in service?


It operates between -25 to 70°C, stores between -40 to 85°C, and is rated for altitudes up to 2000 m.

Which insulation and impulse voltage ratings apply to the control and main circuits?


Rated insulation voltage is 690V with a 6 kV impulse withstand Value and 400V SELV separation between circuits.

How does it behave electrically under overload trip?


The tripping threshold is 14.2xIr ±20% with thermal class 10 performance across 40 to 60 Hz.

Note

'For use with' refers to a compatible power base in amps.

Warning

Schneider are in the process of amending the colour of the TeSys range, from White to Black. This means that the stock you receive could be either of these colours. Please be assured that the colour change in no way affects the Fit, Form or Function of the product.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres