Fluke calibration 8808A/TL 240V 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- RS-stocknr.:
- 260-2798
- Fabrikantnummer:
- 8808A/TL 240V
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.472,34
(excl. BTW)
€ 1.781,53
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- Verzending 2 stuk(s) vanaf 29 oktober 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.472,34 |
*prijsindicatie
- RS-stocknr.:
- 260-2798
- Fabrikantnummer:
- 8808A/TL 240V
- Fabrikant:
- Fluke calibration
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Product Type | Digital Multimeter | |
| Multimeter Type | Bench | |
| Model Number | 8808A/TL 240V | |
| Display Type | Digital | |
| Resistance Resolution | 1mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 750V ac | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum Resistance Measurement | 0.1GΩ | |
| Maximum DC Current Measurement | 10A dc | |
| True RMS | Yes | |
| AC Current Accuracy | ±0.3 % rdg | |
| DC Current Accuracy | 0.02 % rdg | |
| AC Voltage Accuracy | ±0.2 % rdg | |
| DC Voltage Accuracy | ±0.015 % rdg + 0.003 | |
| DC Voltage Resolution | 1 μV | |
| DC Current Resolution | 1nA ac | |
| AC Voltage Resolution | 1μV | |
| AC Current Resolution | 100μA ac | |
| Maximum Frequency | 1MHz | |
| Resistance Measurement Accuracy | 0.02 % rdg + 0.003 % range | |
| Minimum Operating Temperature | 0°C | |
| Series | 8808A | |
| Weight | 2.1kg | |
| Height | 88mm | |
| Width | 217mm | |
| Standards/Approvals | ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | |
| Length | 297mm | |
| Safety Category Level | Connector Bracket, Joint | |
| Safety Category Voltage | 1000V dc | |
| Calibrated | UKAS | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Product Type Digital Multimeter | ||
Multimeter Type Bench | ||
Model Number 8808A/TL 240V | ||
Display Type Digital | ||
Resistance Resolution 1mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum AC Voltage Measurement 750V ac | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum AC Current Measurement 10A ac | ||
Maximum Resistance Measurement 0.1GΩ | ||
Maximum DC Current Measurement 10A dc | ||
True RMS Yes | ||
AC Current Accuracy ±0.3 % rdg | ||
DC Current Accuracy 0.02 % rdg | ||
AC Voltage Accuracy ±0.2 % rdg | ||
DC Voltage Accuracy ±0.015 % rdg + 0.003 | ||
DC Voltage Resolution 1 μV | ||
DC Current Resolution 1nA ac | ||
AC Voltage Resolution 1μV | ||
AC Current Resolution 100μA ac | ||
Maximum Frequency 1MHz | ||
Resistance Measurement Accuracy 0.02 % rdg + 0.003 % range | ||
Minimum Operating Temperature 0°C | ||
Series 8808A | ||
Weight 2.1kg | ||
Height 88mm | ||
Width 217mm | ||
Standards/Approvals ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | ||
Length 297mm | ||
Safety Category Level Connector Bracket, Joint | ||
Safety Category Voltage 1000V dc | ||
Calibrated UKAS | ||
- Land van herkomst:
- CN
Fluke Digital Multimeter, 1kV Maximum DC Voltage, 10A Maximum DC Current - 8808A/TL 240V
Features and Benefits:
• 1μV DC voltage resolution for minute signal detection
• True RMS AC measurements for accurate non-sinusoidal waveform readings
• 10A AC/DC current capability for high-current testing
• 1MHz frequency limit for high-speed signal evaluation
• 0.1GΩ resistance range for large insulation and resistance checks
Applications
• Ideal for power-supply verification and calibration tasks
• Used for frequency response measurement in electronic development
• Can be used for capacitance and temperature characterisation in labs
• Used with maintenance routines requiring continuity and resistance checks
What input protection or safety classification does it offer?
What approvals confirm its adherence to international safety norms?
What measurement stability can I expect for resistance readings?
How Compact and portable is the instrument for bench use?
Gerelateerde Links
- Fluke calibration 8808A/TL 240V 8808A Bench Digital Multimeter True RMS 10 A dc RSCAL Calibrated
- Fluke calibration 8808A/TL 240V 8808A Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- Fluke calibration 8808A/SU 8808A Bench Multimeter True RMS 10 A dc UKAS Calibrated
- Fluke calibration 8808A/SU 8808A Bench Multimeter True RMS 10 A dc RSCAL Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS 10 A dc UKAS Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS 10 A dc RSCAL Calibrated
- Fluke calibration 8808A/SU 8808A Bench Multimeter True RMS 10 A dc, 750 V ac
- Fluke calibration 8808A Bench Digital Multimeter True RMS 10 A dc, 750 V ac