Jumo 201025/51-22-04-22-120/837, Combination Electrode (Glass or Metal Electrodes and Reference Electrodes In One
- RS-stocknr.:
- 279-567
- Fabrikantnummer:
- 201025/51-22-04-22-120/837,
- Fabrikant:
- Jumo
Subtotaal (1 eenheid)*
€ 298,87
(excl. BTW)
€ 361,63
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 08 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 298,87 |
*prijsindicatie
- RS-stocknr.:
- 279-567
- Fabrikantnummer:
- 201025/51-22-04-22-120/837,
- Fabrikant:
- Jumo
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Jumo | |
| Product Type | PH Probe | |
| Measurement Range | 0 to 14 pH | |
| Electrode Type | pH | |
| Probe Type | Combination Electrode (Glass or Metal Electrodes and Reference Electrodes In One Shaft), A Pt1000 Temperature Probe | |
| Standards/Approvals | RoHS | |
| Alles selecteren | ||
|---|---|---|
Merk Jumo | ||
Product Type PH Probe | ||
Measurement Range 0 to 14 pH | ||
Electrode Type pH | ||
Probe Type Combination Electrode (Glass or Metal Electrodes and Reference Electrodes In One Shaft), A Pt1000 Temperature Probe | ||
Standards/Approvals RoHS | ||
- Land van herkomst:
- DE
The Jumo Combined combination electrode (platinum- and reference electrodes in one shaft) has a dirt-repellent PTFE ring diaphragm with polymerized solid electrolyte. Only the selection of high quality materials and components enables the use, for example, in heavily polluted media or adherent media containing oil. The combination electrode was specially developed for use in chromate reduction, nitrite oxidation, swimming pool and drinking water disinfection. It can be used for a redox range of plus/minus 1500 mV and has a temperature resistance of -5 to +90 °C. The insertion length is 120 mm.
Prevents deposits and blockages which ensuring quick response time
Salt rings increase service life of media with fewer ions or high flow rates
Gerelateerde Links
- Jumo 201025/51-22-10-22-120/837 Combination Electrode (Glass or Metal Electrodes and Reference Electrodes In One Shaft),
- Jumo 201025/51-32-07-22-120/837 A Pt1000 Temperature Probe, Combination Electrode (Glass or Metal Electrodes and
- Jumo 201025/72-22-05-22-120/837 Combination Electrode (Glass or Metal Electrodes and
- Jumo 201021/10-12-04-18-120/841 A Pt1000 Temperature Probe, Combination Electrode (Glass or Metal Electrodes and
- Jumo 201021/10-12-04-82-120/000 A Pt1000 Temperature Probe, Combination Electrode (Glass or Metal Electrodes and
- Chauvin Arnoux XCPST4 Clark probe Combination Electrodes Redox Electrodes Measuring
- Jumo 201026/10-22-04-82-120/000 pH and redox combination electrodes pH 0 to 14 pH, 4 to
- Jumo 201020/51-18-07-22-120/837, PH Probe