Fluke 718Ex -12 psi to 100 psi Pressure Calibrator
- RS-stocknr.:
- 479-2450
- Fabrikantnummer:
- FLUKE-718EX 100/APAC
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 5.528,00
(excl. BTW)
€ 6.688,88
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 2 stuk(s) vanaf 28 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 5.528,00 |
*prijsindicatie
- RS-stocknr.:
- 479-2450
- Fabrikantnummer:
- FLUKE-718EX 100/APAC
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Maximum Pressure Measurement | 100psi | |
| Product Type | Pressure Calibrator | |
| Battery Type | Alkaline | |
| Accuracy | ±0.05 % | |
| Minimum Pressure Measurement | -12psi | |
| Resolution | 0.01 psi | |
| Data Logging | No | |
| Model Number | 718Ex | |
| Intrinsically Safe | Yes | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 992g | |
| Maximum Operating Temperature | 55°C | |
| Battery Life | 20h | |
| Length | 216mm | |
| Width | 94mm | |
| Height | 66mm | |
| Standards/Approvals | No | |
| Hazardous Area Certification | ATEX | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Maximum Pressure Measurement 100psi | ||
Product Type Pressure Calibrator | ||
Battery Type Alkaline | ||
Accuracy ±0.05 % | ||
Minimum Pressure Measurement -12psi | ||
Resolution 0.01 psi | ||
Data Logging No | ||
Model Number 718Ex | ||
Intrinsically Safe Yes | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 992g | ||
Maximum Operating Temperature 55°C | ||
Battery Life 20h | ||
Length 216mm | ||
Width 94mm | ||
Height 66mm | ||
Standards/Approvals No | ||
Hazardous Area Certification ATEX | ||
Vrijgesteld
Fluke Pressure Calibrator, 100psi Maximum Pressure Measurement, ±0.05% Accuracy - FLUKE-718EX100
This pressure calibrator is an intrinsically safe, battery-powered handheld instrument designed for pressure and loop current checks in hazardous environments. It integrates a manual pressure/vacuum pump and an internal sensor for precise field measurements, while offering compatibility with intrinsically safe pressure modules for extended ranges.
Features & Benefits
• ±0.05% full-scale pressure measurement for accurate calibration
• 0.01psi resolution enabling fine differential readings
• 0mA–24mA current measurement with 0.001mA resolution for loop checks
• ATEX II 1G Ex ia IIC T4 certification for use in explosive atmospheres
• 20h alkaline battery life for extended field operation
• Built-in vernier pump and bleed valve for controlled pressure application
• 0.01psi resolution enabling fine differential readings
• 0mA–24mA current measurement with 0.001mA resolution for loop checks
• ATEX II 1G Ex ia IIC T4 certification for use in explosive atmospheres
• 20h alkaline battery life for extended field operation
• Built-in vernier pump and bleed valve for controlled pressure application
**Applications**
• Suitable for commissioning and verification of process transmitters in hazardous zones
• Ideal for pressure switch testing and adjustment on site
• Used with intrinsically safe pressure modules to extend measurement to 3000psi
• Can be used for routine loop checks and maintenance of 4–20mA systems
• Ideal for pressure switch testing and adjustment on site
• Used with intrinsically safe pressure modules to extend measurement to 3000psi
• Can be used for routine loop checks and maintenance of 4–20mA systems
What pressure range does it support without additional modules?
The internal sensor covers −12psi to 100psi with specified accuracy and resolution.
How is external module connectivity handled?
Pressure modules attach via a dedicated LEMO connector and the instrument auto-selects the module readout.
What inputs are provided for current and pressure?
Current connects to shrouded banana jacks and pressure uses a 1/8in NPT fitting.
How does temperature affect measurement performance?
Temperature coefficients add up to +0.01% of range per °C outside the 18°C–28°C reference for pressure and specified coefficients for current.
Group and Category
II 2 G EEx ib IIC T4
Supplied with
protective red holster, TL75 test leads, AC72 test clips, media filter, CD instruction manual & content control diagram.
Gerelateerde Links
- Fluke 721 -12 psi to 100 psi Pressure Calibrator
- Fluke 721 -12 psi to 100 psi Pressure Calibrator, RSCAL
- Fluke 717 -1 psi to 1 psi Pressure Calibrator
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator
- Fluke 722 -12 psi to 300 psi Pressure Calibrator
- Fluke 730 -12 psi to 500 psi Pressure Calibrator
- Fluke 730 -12 psi to 500 psi Pressure Calibrator, RSCAL