Eaton FRCdM Series Residual Current Circuit Breaker, 40 A, 4-Pole, 300 mA, Type B, 10 kA, 220 V dc 240 V ac
- RS-stocknr.:
- 183-3548
- Fabrikantnummer:
- 167897 FRCDM-40/4/03-G/B
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 742,13
(excl. BTW)
€ 897,98
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- 3 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 742,13 |
*prijsindicatie
- RS-stocknr.:
- 183-3548
- Fabrikantnummer:
- 167897 FRCDM-40/4/03-G/B
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Series | FRCdM | |
| Range | FRCdM | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type B | |
| Mount Type | DIN Rail | |
| Standards/Approvals | EN 45545-2, IEC/EN 61008, IEC 61373 | |
| Terminal Type | Screw | |
| Height | 80mm | |
| Depth | 70.5mm | |
| Width | 70 mm | |
| Breaking Capacity | 10kA | |
| Tripping Mechanism | Electromagnetic | |
| Application | Industrial | |
| Rated DC Voltage | 220 V dc | |
| Earth Leakage Protection Type | Type B | |
| Rated AC Voltage | 240 V ac | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Series FRCdM | ||
Range FRCdM | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type B | ||
Mount Type DIN Rail | ||
Standards/Approvals EN 45545-2, IEC/EN 61008, IEC 61373 | ||
Terminal Type Screw | ||
Height 80mm | ||
Depth 70.5mm | ||
Width 70 mm | ||
Breaking Capacity 10kA | ||
Tripping Mechanism Electromagnetic | ||
Application Industrial | ||
Rated DC Voltage 220 V dc | ||
Earth Leakage Protection Type Type B | ||
Rated AC Voltage 240 V ac | ||
- Land van herkomst:
- CZ
Eaton 40A Type G/B Residual Current Circuit Breaker - FRCDM-40/4/03-G/B
Digital residual current circuit-breaker, 40A current rating, 4 Pole, 300mA trip sensitivity, type G/B
Eaton Residual Current Circuit Breakers (RCDs) - FRCdM Series Types B, B+ and Bfq
The FRCdM series of residual current devices from Eaton form part of the xEffect range providing the highest RCD protection for both people and appliances. These devices allow for permanent indication of actual electrical leakage with built in digital features.These types B, B+ and Bfq RCCBs detect AC pulsating, DC residual and smooth DC residual currents.
Type B RCCBs are the standard type and are sensitive to all residual current flows up to 1 kHZ. Type B+ devices are sensitive to all residual currents while also being equipped with a special tripping curve that limits the trip current to max. 420 mA for frequencies up to 20 kHz (Type B+ also meets superior fire protection regulations according to VDE 0664-400). Type Bfq devices meanwhile can tolerate system-induced earth leakage currents at higher frequencies up to 50 kHz.
Features and Benefits
• All-current sensitive residual current device for fault or additional protection
• Digital Features
• System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents
• Integrated auxiliary contact
• Local Indication through 3 LEDs
• 4-pole types can also be used as 2-pole devices for photovoltaic applications
• New level of accuracy - reduced unwanted tripping
• No monthly test required
• Comprehensive range of accessories
• Real contact position indicator
• Fault current tripping indicator
• Automatic re-setting possible
• Transparent designation plate
What type of RCD do I need?
An RCD is a protective and potentially life saving device designed to keep electrical installations protected from nuisance trips, short circuits and overloads, whilst also protecting against electric shocks and electrocution when there is bare or faulty wiring, or earth leakage. The device will automatically cut out the power supply when a fault is detected.
Fixed RCDs are commonly installed in a fuse box and can protect multiple circuits. RCDs located within a consumer unit are mostly passive which allows household appliances to re-establish normal operation when the circuit power is reset.
Socket-Outlet RCDs provide individual protection to the person who is in contact with the equipment, making them an integral tool for electricians. They can be used in place of a standard socket outlet. Socket-outlet RCDs are either active or passive. They are latching in operation so are not ideal for power tools which do not require a restart when the circuit is restored.
Portable RCD plugs also only provide individual protection to the person who is in contact with the equipment. They plug-in to any standard socket, and the appliance is then plugged into the RCD. Portable RCDs are mostly active and unlatch when any abnormality is detected. Ideally suited for use with outside power tools which could become dangerous if they were suddenly reactivated.
Note
Eaton formerly known as Moeller
